BAYKAN WALL-HUNG BOILER USER MANUAL
24-30-35 kW MONO- THERMIC ''Type-C"
Our highly esteemed customers,

We would like to thank you for your trust in our company;
Baykan and your decision for purchasing products of Baykan .

Our devices have been manufactured with the latest
technology and they offer you the best comfort of use and
heating.

Condensing Boiler

24kW Sun Premix
30kW Sun Premix
35kW Sun Premix
! 1

Advertisement

loading

Summary of Contents for GasTech BAYKAN Series

  • Page 1: Condensing Boiler

    BAYKAN WALL-HUNG BOILER USER MANUAL 24-30-35 kW MONO- THERMIC ’’Type-C” Condensing Boiler 24kW Sun Premix 30kW Sun Premix 35kW Sun Premix Our highly esteemed customers,
 We would like to thank you for your trust in our company; Baykan and your decision for purchasing products of Baykan .
 Our devices have been manufactured with the latest technology and they offer you the best comfort of use and heating.
  • Page 2: Table Of Contents

    CONTENTS 1. WARNINGS PAGE 3 2. TECHNICAL DATA PAGE 6 3. INSTALLING PAGE 8 4. ADJUSTMENT AND MAINTENANCE PAGE 15 5. USAGE PAGE 19...
  • Page 3: Warnings

    WARNINGS AND SAFETY INSTRUCTIONS For a safe use of your device in conformity with instructions, use your manual carefully. Comply with the operation and mounting instructions specified in the manual.
 The Manufacturing Company is not liable for the damages that arise due to faulty use. The manual must be preserved in order to be presented to the personnel sent for installing and service purposes and kept assuming it may be required in future.
  • Page 4  Have your maintenance provided by Baykan Authorized Technical Service staff and always use 
 original spares. 
 The Changes and Modifications that should not be performed on your wall hung boiler or around its location  After putting your wall hung boiler into operation, never change the water, gas, air supply switches and electricity circuits.
  • Page 5  By means of the supplementary guarantee agreement, you can extend your 
 warranty for 3 more years. 
 The Signs and Symbols Used, 
 Exclamation in a Triangle; means Vital Dangers and material damages on the device.
 Hand Symbols; mean important warnings. 
 Conformity with International Directives and Regulations,  Your device is certified by Turkish Standarts Institute.
  • Page 6: Technical Data

    2.TECHNICAL DATA TECHNICAL DATA BAYKAN SUN PREMIX TECHNICAL DATA UNT. 24kw 30kw 35kw II2H3P Class Nox Type C13-C33-C43-C53-C63 Type Doğalgaz/LPG Type of Gas 22,5 28,0 33,0 Max. heat input 10,0 Min. heat input Max. heat output 21,8 27,2 32,0 Min. heat output 23,7 29,6 34,8...
  • Page 7 Power supply voltage / frequency V/Hz 230(±15V)/50 Electrıcal Power Grade of protection DIMENSIONS AND CONNECTIONS Width Height Depth Weight inç ¾” CH circuit inlet/outlet DHW inlet/outlet 60/100 90˚ Dirsek + 3,5 Gas circuit 90˚ Dirsek + 0,5 Flue pipe diameter Flue pipe length min/max 80/80 1,00 mbar’a eşdeğer...
  • Page 8: Installing

    2.3.BOILER MAIN COMPONENTS FİG 2 1) Air Pressure Switch 10) Flow sensor 2) Het Exchanger 11) Pressure Safety Switch 3) İonization electrod 12) Pump 4) Condensate output 13) Gas Valves 5) Fan 14) Mixer 6) Motorized 3 Way Valve 15) Transformer of Burn 7) Domestic Water Heat Sensor HTC 16) Electrod of Burn 8) Safety Valves...
  • Page 9 !  The volume of your room must be equal to at least 0,6 m3 per each kW of the heat output of your device. Practically you can estimate 1 m3 per each kW, for instance, for a device with heat output of 24 kW, the volume of the room must be 24m3. !  For supplying air for the room where your device is placed, an orifice must be made.
  • Page 10 Minimum 150 cm If these conditions are maintained, the air flow can be supplied from a place nearby : The place nearby must be directly ventilated;
 Only devices connected to the ventilation pipes must be installed in the area to be ventilated;
 The nearby place should not be a garage, barn or storage place where fuels or combustibles are stored;
...
  • Page 11 Caution : The installing area and waste gas discharge area must conform the directives of Gas Distribution Company, TSI and international regulations. 2. PLACEMENT OF THE WALL HUNG BOILER 2.1 MOUNTING THE WALL HUNG BOILER TO THE WALL ! Considering the dimensions of your device and by using the installing and mounting diagram on the packages, determine the positions of wall screws and sign them.
  • Page 12 Perform the followings for a good gas connection. !  Ensure that the Gas pipe is clean, clean around it. !  The building internal gas distribution pipe must conform to the technical specifications and regulations. !  An elastic connection between the device and internal gas line of the building must be made. (3/4”). ! 12...
  • Page 13 !  The proper sealed and hermetic gaskets must be used for spacing connection. !  Inspect and compare the gas inlet pressure values and the gas inlet values of the 
 building. These adjustments are only performed by Baykan Service Headquarters and 
 Baykan authorized personnel.
  • Page 14 Caution: The device must be grounded. 
 Figure 7 The supply cable and voltage must be checked by the authorized staff, the power of wall hung boiler must be measured and compared to the figures specified on the technical label of the wall hung boiler and they must be equal.
  • Page 15: Adjustment And Maintenance

    !  Ensure that the water pressure displayed on the screen is between 1,5 and 2 bars. !  Carry on until the air is evacuated.
 Caution: While operating, always compare the value of the central heating system 
 displayed on screen to the value on the label. 
 3.2 Filling Operation for Baykan Star –...
  • Page 16  By rotating the “A” switch seen on Figure 13-14 upon " symbol (sun), select the 
 summer mode or and if you have the version having a display screen, pres “D” switch 
 seen on figure 15 and pres it until"symbol is displayed.  After loosing the screw, place a mini manometer sinker on pressure socket 1 (figure 
...
  • Page 17  In order to record this data, wait until you go back to the main menu. 
 For Baykan eko star-moon version By rotating unto the # (snowberry) symbol symbolized with “A”, turn the boiler on. Turn the boiler on and check the gas pressure by means of a monometer.
 Adjust the pressure by means of the P2 trimmer seen in the diagram in Figure 5 which is covered by a lid placed behind the display screen.
  • Page 18 Furthermore the said operations must be performed in conformity with regulations and norms in effect.
 At the end of each and every heating period, have your device checked by qualified technicians hence you will own a device operating and performing very well. BEFORE THE MAINTENANCE STAGE, YOU MUST  Check the declaration of conformity.
  • Page 19: Usage

     Inspection of the unobstructed Access of air that causes burning without hindrance; 
 In case of the need for changing some components of wall hung boilers, the original parts supplied by the manufacturer company must be used. Use of foreign parts may risk the efficient and proper running of the wall hung boiler 
...
  • Page 20  Do not let children or people with no prior experience of device operate and use the 
 wall hung boiler  In case of smelling gas, do not turn the lights and electricity switches on, do not use 
 telephone or other such device that may cause sparks, immediately open doors and Windows, turn the gas tap off, finally demand the assistance and service of qualified personnel to correct the factors which caused the said leakage.