Determining The Failures Of Device - GasTech 24kW Baykan Starplus Manual

24-28-32 kw mono-thermic c type hermetic wall hung boilers, 24-28 kw mono-thermic b type flue duct wall hung boilers, 24 kw bithermic type-c hermetic wall hung boiler
Table of Contents

Advertisement

KE
= The variable value determined by the user
T base
=The base temperature determined as 40° concerning the systems with radiators.
laid on floor.
Concerning the HIGHER version only (the model with display screen)
THE FUNCTION OF THIS
SWITCH

5. DETERMINING THE FAILURES OF DEVICE

The abnormal conditions that may arise while the wall hung boiler is operating will be informed by the
codes or signs that are displayed on the display screen on the control panel indicating the situations
that cause the abnormality, concerning the version with display screen while concerning the versions
with Led, it is informed with one or more Leds flash simultaneously.
E 01 or LED 80°
BLOCKED
If the boiler can not be ignited, (following the wall hung boiler attempting to ignite three times) wall
hung boiler must have its RESET button marked with "E" in the version with display or its RESET
button marked with "A" in the version with switch moved unto (R-RESET) momentarily to remedy
this situation.
If the said situation frequently happens, you must contact an authorized dealer.
E 02 or LED 60°
MEASURER BEING BROKEN
This sign is displayed if the fume pressure measurer does not let wall hung boiler to ignite. In this
case, the wall hung boiler is blocked; it can go back to its position momentarily by pressing the "E"
marked reset button in the version with display and by pressing "A" in the version with switch.
If the problem still exists, there is need for the assistance of authorized technical service.
E 03 or LED 30°
NEEDING TO BE SERVICED DUE TO AGE
This sign is displayed when the heating thermostat runs improperly, the wall hung boiler is
blocked, it must be serviced by an authorized technical service.
E 04 or LED 40°
NEEDING TO BE SERVICED DUE TO ITS AGE
The symbol is displayed when the tap water thermostat runs inefficiently. Wall hung boiler runs
without its function of checking and controlling the tap water temperature. The tap water function
is completely lost concerning the 24 kW baykan eko bithermic wall hung boiler. It needs to be
serviced by an authorized technical service.
E 08 or LED 50°
INSUFFICIENT
It is displayed, as the pressure of the heating system goes down to 0,6 bars, this results with the
stand-by condition of the wall hung boiler and will carry on until the operating pressure has not
been changed to its previous condition. In order th change the pressure into its previous
condition, it is sufficient that you fill the system as defined in the paragraph having the title
'CHECKONG THE PRESSURE OF HEATING SYSTEM".
If this condition carries on, you need to call an authorized technical service.
E 09 or LED 70°
BE ACTIVATED
It is displayed when the temperature of the water in Primary system exceeds 100°C-(concerning 24
kW Bywarm Star bithermic wall hung boiler 95°C ), in which case the wall hung boiler is blocked.
In order to deactivate the alarm condition, press RESET button marked with "E" in the version
having a display screen or press the button marked with "A" in order to go back to RESET
position. The wall hung boiler will ignite again only if the temperature of water in the system goes
below 60° or 55 °C.
BAYKAN ISI SIST.SAN.TIC. AS.
30° is the base temperature concerning the installations
In order to control with the external thermostat, it is sufficient to press
button which has the function of keeping the previously set up parameters
("F") is enough. This allows us to monitor the previously recorded value of
the environment thermostat in the part of area marked with 3, with 2, the
temperature determined by the external thermostat and with 1, the
previously recorded "KE" value.
THE SYMBOL DISPLAYED IN CASE OF NOT IGNITING OR BEING
THE CODE DISPLAYED IN CASE OF THE AIR PRESSURE
THE CODE DISPLAYED IN CASE OF THE HEATING THERMOSTAT
THE CODE DISPLAYED IN CASE OF THE TAP WATER THERMOSTAT
THE CODE DISPLAYING THAT THE PRESSURE OF THE SYSTEM IS
THE CODE DISPLAYING THAT THE SAFETY THERMOSTAT MUST
- 22 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

28kw baykan starplus24kw baykan sun24kw baykan moon28kw baykan sun32 kw baykan sun28kw baykan moon

Table of Contents