1. WARNINGS FOR THE USER
The handbook of directives hereby is integral and supplementary part of the product thus preserve it
•
close to the device all times. Ensure that the manual is with the wall hung boiler when the device is
sold or delivered to another user.
The installing, adjusting and starting up operations must be performed by qualified professionals..
•
The conversion procedures for the device to operate on a different type of gas than specified must
•
be performed by qualified professionals. The said person must check that the data on the plate and
all adjustment elements and set ups are in conformity with the specified use of the device.
Always check that the pipes for the discharge of wastes caused due to combustion function weel
•
and always check if they are properly closed.
Always be sure that the air flow at the locations and areas where the device is installed is correct. If
•
there is lack of proper ventilation, mixture of poisonous and explosive gases may accumulate in the
area, besides aspirators, ducts or similar devices should not be used with wall hung boiler
simultaneously at the locations where the wall hung boiler is installed.
Do not touch lid, fume hood uptake, flu duct etc. parts of wall hung boiler due the risk of danger, do
•
not let children or persons with no mechanical experience come close to the location where wall
hung boiler is being serviced.
Do not let the wall hung boiler be subject to direct fume.
•
Do not let the wall hung boiler become wet with splashing of water or other liquids.
•
Do not lean any objects onto the wall hung boiler.
•
Do not let children or people with no prior experience of device operate and use the wall hung boiler
•
In case of smelling gas, do not turn the lights and electricity switches on, do not use telephone or
•
other such device that may cause sparks, immediately open doors and Windows, turn the gas tap
off, finally demand the assistance and service of qualified personnel to correct the factors which
caused the said leakage. It is recommended that gas leak detection devices should be used at
proper locations in areas where the wall hung boiler is installed.
If the wall hung boiler is not used for a long period of time, turn off the main gas supply tap and cut
•
the electricity leading to the wall hung boiler.
The wall hung boiler is controlled by a device against freezing on its control card, the mentioned
•
function activates when the water temperature inside the installation goes below five degrees
however the wall hung boiler must be connected to electricity for that. As the water temperature
reaches 12°C, the wall hung boiler will turn off automatically however the circulating device will
continue operating for 180 seconds.
Frequently check the figure displayed by the pressure gauge on the control panel of wall hung
•
boiler, the said value must be 1,5 to 2 bars.
If the device is completely put out of use, the mentioned procedures must be performed by the
•
qualified personnel.
3. IGNITING, FUNCTIONS AND TURNING IT OFF
PRELIMINARY INSPECTIONS
The following matters must be check at the first igniting and turning on stage of the wall hung boiler:
Ensure that the cut off valves between wall hung boiler and installation are on;
-
Ensure that the air of installation is completely taken and filled;
-
-
Check that the wall hung boiler has been designed in conformity with and suitable for the gas to be
used;
-
Check if there are any gas or water leakages in the installation or wall hung boiler.;
-
Check that the electricity connections have been properly made and the grounding is connected to a
good grounding installation.;
-
Ensure that there are no flammable liquids or materials near the wall hung boiler;
-
Check if the fume and smoke discharge pipe is on;
-
Check if any remote programmer thermostat is ON.