Download Print this page

Removing The Belt In The Event Of Unit Failure - RADEMACHER RolloTron Standard Series Operating And Assembly Manual

Electronic roller shutter belt winder

Advertisement

Available languages

Available languages

i

16. Removing the belt in the event of unit failure

In the event that the roller shutter belt winder unit fails and
the motor no longer runs, you can use the disengaging
bracket provided in order to fully remove the belt from the
belt winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket or switch off
the mains power supply.
2.
Dismantle the roller shutter belt winder as previously
demonstrated on page 96.
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆ Secure the roller shutters from falling, for example,
by laying something underneath it.
◆ Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆ Get a second person to help you unlatch the unit.
3.
Release the drive with the help of the supplied disen-
gaging bracket.
A small amount of resistance must be overcome when
pressing.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the roller shutter belt winder as far as
possible.
98
5.
Release the belt from the fastening hook and pull it out
completely from the roller shutter belt winder.
6.
Replace the disengaging bracket in its holder.
Standard
device
Device for
large belt
boxes
EN
Drive
release
Storage bay
Drive
release

Advertisement

loading

This manual is also suitable for:

Rollotron standard plus