Appendix B
Specifications
Power Requirements
Power Rail
+3.3 V
+5 V
+12 V
+5 VAux
-12 V
Environment
Maximum altitude
Pollution Degree
Indoor use only.
Operating Environment
Ambient temperature range
Operating relative humidity
Storage Environment
Ambient temperature range
Relative humidity range
B-28 | ni.com
Typical Current
2.5 A
10 µA
750 µA
0.3 A
0 A
2,000 m
2
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F
Class 3 low temperature limit and
MIL-PRF-28800F Class 2 high temperature
limit.)
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
-40 to 71 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F
Class 3 limits.)
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56)
Maximum Current
3 A
3 mA
1 mA
0.4 A
0 A