Appendix B
Specifications
Storage Environment
Ambient temperature range
Storage relative humidity
Shock and Vibration
Operational shock
Nonoperating shock
Random Vibration
Operating
Nonoperating
Safety
This product is designed to meet the requirements of the following standards of safety for
electrical equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
For UL and other safety certifications, refer to the product label or the
Note
Product Certification
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for
electrical equipment for measurement, control, and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
B-22 | ni.com
-40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.)
50 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.)
5 to 500 Hz, 0.3 g
5 to 500 Hz, 2.4 g
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
section.
rms
rms