Power Requirements
Power Rail
+3.3 V
+5 V
+12 V
-12 V
VIO
Environment
Maximum altitude
Pollution Degree
Indoor use only.
Operating Environment
Ambient temperature range
Operating relative humidity
Storage Environment
Ambient temperature range
Relative humidity range
Shock and Vibration
Operational shock
Typical Current
420 mA
13 mA
10 mA
0 A
0 A
2,000 m
2
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
-40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.)
MXI-Express x1 Series User Manual
Maximum Current
650 mA
15 mA
12 mA
0 A
1 mA
© National Instruments | B-17