Maintenance and troubleshooting
Maintenance plan
Maintenance plan
Interval
Before commissio-
ning/regularly
Weekly
Monthly
Once a year
After 100,000 opera-
ting hours
As recommended by
the manufacturer.
94
Maintenance work
Assembly workstation with Multilift II ESD lifting column:
Check the effectiveness of the electrical connection in the
lifting column before commissioning and afterwards during
operation, regularly within the scope of ESD monitoring.
Check the assembly workstation for soiling. If necessary,
clean the assembly workstation with a clean cloth.
Note: Do not use cleaning agents containing solvents!
Inspect the electrical connections of the lifting columns for
mechanical stress and to make sure they are firmly in place.
Check the assembly workstation (in particular the lifting col-
umns) for damage (visual inspection).
Carry out a safety inspection of the lifting columns as per
EN 62353.
Check that the limit switches/end positions of the lifting col-
umns are fully functional.
Assembly workstation with Multilift II impact lifting
column:
Replace the lifting columns after 100,000 impact loads with
maximum impulse.
Service the optional modules as per the corresponding
instructions.
Ä Instructions for the optional modules
Assembly workstation RK Easywork
Personnel
Assembly staff
Assembly staff
Qualified electrician
Assembly staff
Assembly staff
Assembly staff
Assembly staff
Assembly staff
Qualified electrician
29.05.2019

Advertisement

Chapters

loading
Need help?

Need help?

Do you have a question about the RK Rose+Krieger Easywork and is the answer not in the manual?

Questions and answers