Page 1
Gas Fireplaces B41XTCE Gas Fireplace Model B41XTCE-NG11 B41XTCE-LP11 Fuel Type Natural Gas Propane Minimum Supply Pressure 5” W.C./C.E. (1.25 kPa) 11” W.C./C.E. (2.74 kPa) Manifold Pressure - High 3.5” W.C./C.E. (0.87 kPa) 10” W.C./C.E. (2.49 kPa) Manifold Pressure - Low 1.6”...
Page 2
Gas Fireplaces B41XTCE-11 Gas Fireplace CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
Gas Fireplaces B41XTCE-11 Gas Fireplace MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Mantel Clearances Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is Combustible made of metal studs covered with a non-...
Gas Fireplaces B41XTCE-11 Gas Fireplace FRAMING & FINISHING 1. Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2.
Page 5
Gas Fireplaces B41XTCE-11 Gas Fireplace 7. Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel. NOTE: Non-combustible finishing materials may be of any thickness desired.
Gas Fireplaces B41XTCE-11 Gas Fireplace VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS FOR HORIZONTAL TERMINATIONS The shaded area in the diagram shows all allowable combinations of The diagram shows all allowable combinations of vertical runs with straight vertical and offset to vertical terminations, using two 90 elbows, horizontal terminations, using one 90 (two 45...