Maintenance
Check the coolant level daily by inspecting the
level in coolant overflow jug located near the
radiator. Refer to the engine operator's manual for
coolant recommendations and proper mixture.
Normal operating level is between the 'full' and
'add' markings on the overflow jug.
AFTER
ENGINE
COMPLETELY COOL, coolant may be added
directly to the coolant overflow jug.
Check the oil level daily. Refer to the engine
operator's manual for the appropriate oil specification.
Verify the oil is correct for special operating conditions
such as a change in season or climate.
DO NOT start the unit if the engine oil level is below
the add mark on the dipstick.
Normal operating level is in the cross-hatch pattern
between the full and add markings on the dipstick.
Add oil only if the oil level is below the add mark on
the bottom of the cross-hatch pattern on the dipstick.
DO NOT OVERFILL the crankcase.
Check the fuel level.
Item
Check Oil Level
Check Coolant Level
Check Fuel Level
Check Tire Pressure
Check All Electrical Connections
Inspect Radiator Fins For Debris, Clean As Required
Inspect Light Tower Winch For Proper Operation
Fuel Tank - Drain Water
Check Air Cleaner
Belt And Belt Tension - Inspect And Adjust
Replace Fuel Filter
Drain And Clean Fuel Tank
Check Glow Plugs
Lubricate Leveling Jacks
Replace Engine Oil And Oil Filter
Bolts And Nuts On The Engine - Retighten
Replace Heated Fuel Filter (If Equipped)
Inspect Engine Starting Battery
Air Cleaner Element - Clean, Check And Replace
Fuel System - Bleed Air
Water Sedimenter - Drain Water
*
Perform after the initial 50 hours of operation, then on the regularly scheduled interval indicated in the schedule above.
**
Certain conditions may require the fuel tank to be drained and cleaned more often. When operating in extremely
dusty conditions, clean the fuel tank as often as necessary.
^
Applies to units with serial number 1506075 and higher.
22
IS
STOPPED
AND
Basic Maintenance Guide—Mitsubishi Engine
Daily
If the unit is connected to a remote start or transfer
switch, make sure the remote switch is also off and
tagged.
NOTE: If the engine was run out of fuel or the fuel tank
was drained, it may be necessary to bleed the fuel lines.
Refer to the engine operator's manual supplied with the
unit.

Basic Maintenance Schedule

Refer to the original equipment manufacturer's operating
manual for a complete list of maintenance requirements.
Failure to comply with the procedures as described in the
engine operator's manual will nullify the warranty,
decrease performance and cause equipment damage or
premature equipment failure. Maintenance records may
be required to complete a warranty request.
Use the schedule in the following table as a guide for
regular
maintenance
replacement copies of the engine operator's manual,
contact a GMASD.
50
250
400
500
Hr
Hr
Hr
Hr
**
*^
Owner's Manual for Mobile Light Tower
intervals.
For
additional
750
1,000
Hr
Hr
Required
*
or
As

Advertisement

Table of Contents
loading

Table of Contents