Operation
2. See
Figure
3-5. Turn the key on the Engine Start
switch to the left GLOW PLUG position and hold
the key in place for 10-15 seconds or until the glow
plug indicator turns red (if equipped).
GLOW
PLUG
Figure 3-5. Activate Glow Plug
3. See
Figure
3-6. Turn the key to the right START
position and hold it until the engine cranks and
starts running.
CAUTION
Equipment Damage. Do not continuously crank
engine for more than ten seconds. Doing so will lead
to overdischarge of batteries and starter seizure.
GLOW
PLUG
Figure 3-6. Crank Engine
4. See
Figure
3-7. Release the key, it will move to the
RUN position.
NOTE: For cold weather conditions, refer to the engine
operator's manual for appropriate glow plug interval.
NOTE: If oil pressure is not obtained within 15 seconds
after the key is switched to the RUN position, the low oil
automatic shutdown will turn off the fuel supply, stopping
the engine. Check the oil level and turn the key to the
OFF position to reset the oil pressure timer before
attempting to restart the engine.
16
OFF
RUN
START
(000230)
OFF
RUN
START
GLOW
PLUG
5. Once the engine is running, allow it to reach
003792
normal operating temperature before switching on
any loads.

Automatic Shutdown

This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system will automatically shut off the fuel supply to stop
the engine if oil pressure drops too low or the engine
exceeds normal operating temperature. Return the main
circuit breaker to the OFF position to reset the unit after
the cause of shutdown has been determined.

Light Operation

Burn hazard. Never operate lights with a
damaged or missing lens cover. Lamps are
hot and pressurized while in use. Unprotected
lamps can shatter, causing severe injury.
1. Verify the unit is on and running smoothly.
2. See
Figure
(I).
003793
3. Switch the individual circuit breakers for the lights
(B) ON (I), one at a time.
4. The ballast indicator lights (C) will turn on and
continue to get brighter as the lights warm up, and
then remain on. This confirms power is coming
from the ballasts to the lights.
OFF
RUN
Figure 3-7. Release Key
WARNING
3-8. Switch main circuit breaker (A) ON
Owner's Manual for Mobile Light Tower
START
003794
(000277)