Emergency Stop Switch; Starting The Unit - Generac Power Systems MLT4150 Owner's Manual

Light tower
Hide thumbs Also See for MLT4150:
Table of Contents

Advertisement

3. Check the mast cables for excessive wear or
damage. Verify the cables are properly centered in
each pulley (B). Check the electrical cord for
damage.
4. Verify the area around the unit is clear before
raising the mast to vertical position.
5. Remove the safety pin from the mast lock bar (C).
Using the handle for the lower mast winch (D),
raise the mast until it is vertical and the tab on the
mast is positioned into the mast lock. The mast
lock bar should snap into place automatically.
Secure the lock with the safety pin (E).
6. After the mast is up and locked into place, use the
upper mast winch (F) to telescope the mast to the
desired height. Extend the mast slowly, making
sure the electrical cord is extending at the top
sections of the mast. Do not extend past the
colored mark (G).
IMPORTANT NOTE: Contact a GMASD immediately
if the mast hangs up or the winch cable develops
slack.
7. Rotate the mast by loosening the mast rotation
knob at the bottom of the mast (H). Turn the mast
until the lights face in the desired direction and
then tighten the knob.
WARNING
Tipping hazard. Do not extend the mast beyond the
colored mark on the second mast section. The unit
can become unstable and tip or fall, causing injury.
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
WARNING
Personal injury or equipment damage. Do not raise
or lower the mast while the unit is operating.
Doing so can break the lenses and cause the
lamps to shatter.

Emergency Stop Switch

The unit is equipped with one emergency stop switch.
For location of the emergency stop switch, refer to
Component
Locations. The red switch is clearly labeled
"EMERGENCY STOP." The switch can be accessed and
activated with all doors closed and locked.
Activate the emergency stop switch by pushing the red
button in until it locks down.
Owner's Manual for Mobile Light Tower
The switch will remain closed until it is pulled out.
NOTE: Use the emergency stop switch only when the
unit must be shut down immediately. For any other shut
down, refer to

Starting the Unit

NOTE: If the engine was run out of fuel or the fuel tank
was drained, it may be necessary to bleed the fuel lines.
Refer to the engine operator's manual supplied with the
unit.
1. See
individual circuit breakers for each of the lights are
OFF (O).
Equipment Damage. Never start the engine with
circuit breakers switched on. Any load connected
to the generator at start up will cause severe
damage or destroy the generator.
(000262)
NOTE: If the red light on the control panel TURN MAIN
BREAKER OFF is illuminated when the key is turned to
the START position, the breaker is closed (switched on)
and must be turned OFF (O).
(000265)
(000279)
Figure 3-4. Circuit Breakers in OFF (O) Position
Shutting Down the
Unit.
Figure 3-3. Emergency Stop
Figure
3-4. Verify the main circuit breaker and
WARNING
I
I
O
O
Operation
002393
(000368)
I
I
O
O
003791
15