Basic Maintenance Schedule - Mitsubishi Engine - Generac Power Systems MLT3080KV Operating Manual

Light tower
Table of Contents

Advertisement

BASIC MAINTENANCE SCHEDULE - MITSUBISHI ENGINE

Refer to the original equipment manufacturer's operating manual for a complete list of
maintenance requirements. Failure to comply with the procedures as described in the engine
operator's manual will nullify the warranty, decrease performance and cause equipment
damage or premature equipment failure. Mainenance records may be required to complete
Use the schedule in the following table as a guide for regular maintenance intervals. For additional or replacement
copies of the engine operator's manual, contact an authorized dealer in your area.
Item
Check Oil Level
Check Coolant Level
Check Fuel Level
Check Tire Pressure
Check All Electrical Connections
Inspect Radiator Fins For Debris, Clean As
Required
Inspect Light Tower Winch For Proper Operation
Fuel Tank - Drain Water
Check Air Cleaner
Replace Engine Oil And Oil Filter
Belt And Belt Tension - Inspect And Adjust
Replace Fuel Filter
Drain And Clean Fuel Tank
Check Glow Plugs
Lubricate Leveling Jacks
Bolts And Nuts On The Engine - Retighten
Replace Heated Fuel Filter (If Equipped)
Inspect Engine Starting Battery
Air Cleaner Element - Clean, Check And Replace
Fuel System - Bleed Air
Water Sedimenter - Drain Water
*
Perform after the initial 50 hours of operation, then on the regularly scheduled interval indicated in the schedule
above.
**
Certain conditions may require the fuel tank to be drained and cleaned more often. When operating in extremely
dusty conditions, clean the fuel tank as often as necessary.
a warranty request.
50
250
Daily
Hours
Hours
*
400
500
1000
Hours
Hours
Hours
Required
**
*
As
25