If there is more than one monitor connected to the aircraft's RS-485 controller system,
then it is strongly recommended to connect the system in series, or daisy-chain, and
terminate the twisted pairs with a 120 OHM resistor. This configuration improves the
reliability of the system.
It is highly recommended to use 22 AWG twisted pairs for runs longer than 20 feet.
Connect all RS-485A pins together, all RS-485B pins together.
Setting ID Numbers for Multiple Monitors:
When two or more monitors are installed on the same RS-485 Network, an ID number
must be assigned to each monitor. To assign an ID:
Press the menu button (either on the monitor or remote control)
Navigate to the "image" tab
Navigate down to "set ID"
Press left or right to assign a number to the monitor