SERVICE PROGRAM MODE
5
Mode Number/Name
828*
28*
Network Time Server
Address Setting
29*
Network DNS Server
Address Setting
30*
Network Directprint Port
Number Setting
31*
Network IPP Timeout
Setting
32
Network IPX Address
Setting (NetWare)
33*
Network Remote
Printer Number Setting
(NetWare)
34*
Network Software
Switch Setting
(NetWare)
35*
Network Transport
Protocol of Print Server
Setting (NetWare)
36
Network AppleTalk
Module Setting
37
Network NetNo Setting
(AppleTalk)
38
Network Object Name
Setting (AppleTalk)
39*
Network AppleTalk
Type Setting
40
Network Working Zone
Setting (AppleTalk)
47*
Network Job Analysis
Timeout Setting
(Centronics)
48*
Network Job Timeout
Setting (Centronics)
49*
Network Noise Cancel
Setting (Centronics)
50*
Network 1284
Compatibility Setting
(Centronics)
51*
Network Data Transfer
Speed Setting
(Centronics)
52*
Network ECP Setting
(Centronics)
Function/[Setting]
Sets the time server address for the network.
[00000000~FFFFFFFFh / 00000000h / 1 hex unit step]
Sets the DNS server address for the network.
[00000000~FFFFFFFFh / 00000000h / 1 hex unit step]
Sets the directprint port number for the network.
[1024~65535 / 9100 / 1 step]
Sets the IPP timeout for the network.
[30~65535 / 900 / 1 step]
Sets the IPX Address.
Sets the remote printer number for the network.
[0~254 / 0 / 1 step]
Sets the software switch for the network.
[0000~FFFFh / 0003h / 1 hex unit step]
Sets the transport protocol of the print server for the
network.
0000h: TCP & IPX
0100h: TCP& IPX (Priority: IPX)
0102h: TCP Only (Priority: TCP)
0001h: IPX Only
Sets the AppleTalk module for the network. DFU
2: EtherTalk Phase2
Sets the NetNo of the AppleTalk network.
Sets the object name of the AppleTalk network.
Sets the AppleTalk type for the network.
Sets the AppleTalk working zone for the network.
Sets the Centronics job analysis timeout for the
network.
[0~43200 s / 3 s / 1 sec. step]
Sets the Centronics job timeout for the network.
[0~43200 s / 0 s / 1 sec. step]
Sets the noise cancel level for the network.
[4~7 / 4 / 1 clock per step]
Switches Centronics IEEE1284 compatibility on/off for
the network.
0: Disabled, 1: Enabled
Selecting "0" disables bi-directional data transmission.
Sets the Centronics transfer speed for the network.
0: SLOW, 1: FAST
If you select "0" there will be a 120 µ s delay from the
STP signal to the data transfer. (With 1: FAST there is
no delay.)
Switches the ECP setting for Centronics off/on.
0: Disabled, 1: Enabled
With "1" selected, SP5-828-050 must be enabled for
1284 mode compatibility.
4-38
10 August, 2001