Change Password - Bahco TAWM Series Original Instructions Manual

Standard and slim electronic torque-angle wrench with memory
Hide thumbs Also See for TAWM Series:
Table of Contents

Advertisement

TAWM SERIES
Note: Clock Date and Time must be set and Cal interval enabled before calibration countdown
will function (see Setting Date and Time and Setting Calibration Interval).
Note: Calibration Countdown is number of days before wrench is locked out from use following
an expired Cal interval. Countdown number of days before lockout is displayed below "CAL
NEEDED" message:
Note: "CAL NEEDED" message will be displayed on power up and after a re-zero. Applying
torque while countdown is remaining, torque or angle is immediately displayed. Red LEDs and
buzzer turn on if Cal interval has expired. Pressing ENTER button after Cal interval has expired
will display Password Entry screen (Refer to TAWM Calibration manual).
Note: An entered Cal Countdown value of 0 days will disable calibration countdown and if Cal
interval is enabled, wrench does not lock when CAL NEEDED" message is displayed.

CHANGE PASSWORD

Change Password function allows user to change password to a new password. Default password is
required to initially change the password (Refer to Calibration Manual for Configure password).
1. From Configure menu, use UP/DOWN buttons to highlight CHANGE PASSWD selection then press
ENTER button.
2. Initial password entry screen is displayed.
3. Enter default password if changing for first time, otherwise enter current user password using UP/
DOWN buttons to change each digit followed by ENTER button.
4. Change password entry screen is displayed.
5. Enter new password using UP/DOWN buttons to change each digit followed by ENTER button.
6. Confirm password entry screen is displayed.
7. Re-enter new password using UP/DOWN buttons to change each digit followed by ENTER button.
STD
SLIM
Note: Pressing POWER button at any time aborts password change sequence.
Note: If an invalid password is entered during the confirmation step, Invalid Password Match
screen is displayed and new password is not accepted.
STD
ASSET # (ONLY ON SLIM WRENCHES)
This function displays a USB configurable 15-character string. When configured, Asset # string is down-
load data file name and is included in first row of.csv data file.
1. From Configure menu, use UP/DOWN buttons to highlight ASSET # selection then press ENTER
button.
2. ASSET # screen is displayed.
3. Use Windows program to configure Asset # via USB (Contact factory for software).
4. Press ENTER button to accept selection and exit to Configure menu.
Note: While Asset # is being displayed, number can be configured via USB.
Note: Available characters for Asset #: 0-9, A-Z, space # _ % ' ( ) + , - .
Note: If Asset # is blank, wrench serial number is used for .csv file name and included in data.
SLIM
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents