Note: Pressing ENTER button while EXIT menu selection is highlighted will exit without deleting PSET.
Note: When a PSET is deleted, all other stored PSET's will retain their original PSET numbers.
When a new PSET is entered, it will be assigned first available PSET number in sequence.
STD

ADVANCED SETTINGS

Advanced settings are accessed from SETTINGS menu selection on main menu.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight SETTINGS menu selection using UP/DOWN buttons.
3. Press ENTER button to display Settings menu.
Menu Selections:
EXIT - Exits Settings menu and returns to target screen.
SHOW INFO - Displays wrench operational information.
SLEEP TIME - Displays power down interval setup screen.
LCD CONTRAST - Displays LCD contrast setup screen.
KEY BEEP - Displays button press beep enable/disable setup screen.
TARGET BEEP - Displays target beep enable/disable setup screen (only on SLIM wrenches).
AUTO BACKLIGHT - Displays auto backlight enable/disable screen to turn on backlight during
measurement.
TOGGLE BACKLGHT - Displays BACKLIGHT button toggle or timeout enable/disable screen.
VIBRATOR CONFIG - Displays vibrator ON/OFF configuration for when target reached.
BATTERY TYPE - Displays the battery type selection screen (only on SLIM wrenches).
4. To exit Settings menu and return to target torque or angle screen, press ENTER button while EXIT
menu selection is highlighted.
STD
SLIM
SLIM
Note: All user configurable settings are stored in non-volatile memory and are retained while
power is off.
SHOW INFO
Show Info menu selection displays wrench operational information.
1. From Settings menu, press ENTER button while SHOW INFO selection is highlighted.
2. SHOW INFO screen is displayed.
3. UP/DOWN buttons are used to scroll screen.
Operational Information:
SN: Serial number assigned to wrench.
CAL: Date of last wrench calibration.
ISD: In-Service Date.
TCF: Torque Calibration Factor.
ACF: Angle Calibration Factor.
VER: Software version.
OVR CNT: Overtorque Counter tracks how many times an over-torque event occurred on wrench
(torque >125% of full scale).
AZZ: Angle Z-Axis Zero Offset (only on SLIM wrenches).
AZX: Angle X-axis Zero Offset (only on SLIM wrenches).
AZO: Angle Zero Offset at full scale torque (only on SLIM wrenches).
TFS: Torque full scale value (only on SLIM wrenches).
Copyright (only on SLIM wrenches).
TQZ: Torque Zero Offset.
ANZ: Angle Zero Offset (only on SLIM wrenches).
4. Pressing ENTER button exits Show Info screen and returns to Settings menu.