Bahco TAS Series Original Instructions Manual

Bahco TAS Series Original Instructions Manual

Standard and slim electronic torque-angle wrench and electronic torque-angle screwdriver

Advertisement

TAW AND TAS SERIES
STANDARD AND SLIM
ELECTRONIC TORQUE-ANGLE WRENCH
AND ELECTRONIC TORQUE-ANGLE SCREWDRIVER
Original Instructions
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TAS Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Safety Instructions
Hazard Warnings
Risks of flying particles, breakage, injury from broken tools, slippage due to over-torquing, calibration errors.
Safe Usage Practices
Wear safety goggles, ensure component ratings, use correct/undamaged sockets, avoid power off, measure torque, do not press power, do not break fasteners loose.
Manual and Maintenance Guidelines
Read manual, ensure stability, follow practices, recalibrate, check capacity, verify calibration.
Additional Safety and Electrical Precautions
Additional Safety and Electrical Precautions
Proper flex head use, safe stance, battery handling, storage, electrical shock hazard, disclaimer.
Specifications
Wrench and Screwdriver Head Types
Details on available head types for wrenches and screwdrivers.
Display and Controls
Information on the tool's display, button functions, and overall interface.
Tool Functions and Accuracy
Describes core functions like target setting, peak hold, memory recall, and measurement accuracy.
Performance Specifications
Covers torque accuracy, operating/storage temperatures, measurement drift, humidity, and battery types.
Advanced Features
Details on auto shut-off and static dissipative properties.
User Instructions
Tool Identification and Setup
Diagrams of SLIM/STD and SCR models, including battery installation and power-on sequence.
Powering On and Mode Selection
Detailed steps for turning on the tool and selecting measurement modes.
Torque and Angle Zeroing
Procedures for zeroing torque and angle measurements on STD and SLIM/SCR models.
Setting Target Torque
Steps to set target torque value and select units of measure.
Applying Torque and Angle Measurement
Procedures for applying torque and rotating the tool for angle measurement.
Peak Readings and Cycle Count
How to recall peak torque/angle readings and understand the cycle count feature.
Main Menu and Settings
Main Menu Navigation
Accessing and understanding the main menu options.
Setting Head Length for TAW Wrenches
Procedure to adjust head length for accurate measurements with TAW wrenches, including offset usage.
Head Length and Offset Usage
Explanations for fixed/interchangeable heads, adapters, and negative offset usage.
Viewing Stored Data
Viewing Stored Torque and Angle Data
Steps to access and review recorded torque and angle measurements, including data format and memory limits.
Stored Data Display Examples
Examples of how stored data is presented for different tool models.
Deleting Stored Data
Deleting Stored Torque and Angle Data
Procedure to clear all recorded torque and angle data from the tool.
Tool Counter Operations
Viewing and Clearing Cycle Counter
How to check the tool's cycle count and reset it to zero.
Language and Display Settings
Selecting Tool Language
Steps to choose the preferred language for the tool's interface.
Decimal Mark Selection
Option to select comma or decimal point as the separator for downloaded data.
Preset Configuration
Target Presets Overview and Adding Torque Presets
Introduction to PSETs and steps to add torque presets, including min/max values and batch count.
Adding Angle Presets
Steps to add angle presets, including min/max angle and batch count.
Editing Presets
Procedures for modifying existing presets.
Deleting Presets
Procedures for removing unwanted presets.
Advanced Settings
Accessing Advanced Settings
How to enter the Advanced Settings menu from the main menu.
Tool Information and Sleep Time
How to view tool operational data and configure the automatic sleep time interval.
Display and Audio Settings
Procedures for adjusting LCD contrast and enabling/disabling key press beeps.
Target Beep and Auto Backlight
Configuration for target beep feedback and automatic backlight activation during measurements.
Backlight Toggle Function
Setting to enable or disable the backlight toggle feature for continuous illumination.
Vibrator and Battery Type Configuration
Settings for vibrator activation and selecting battery type for optimal performance.
Advanced Configuration
Configuration Menu Navigation
Accessing the main advanced configuration options.
Mode Setup and Preset Management
Configuring measurement modes and managing saved presets.
Torque THEN Angle Mode Configuration
Enabling or disabling the Torque THEN Angle measurement mode.
Deleting All Presets
Procedure to remove all saved presets from the tool.
Date, Time, and Calibration Settings
Setting the tool's clock and configuring calibration reminders.
Setting Date and Time
Steps to set the tool's current date and time.
Setting Calibration Interval
How to set the calibration interval and related options.
Calibration Interval Details
Understanding the calibration interval calculation and related notes.
Troubleshooting
Common Issues and Resolutions
Guide to diagnosing and resolving common problems like power issues, incorrect readings, and errors.
Important Information and Maintenance
Accessories and Calibration Guidance
Usage guidelines for accessories and information on calibration services.
Tool Maintenance and Error Indicators
Instructions for cleaning, troubleshooting error messages, and understanding memory indicators.
Battery Replacement Procedures
Step-by-step guide for replacing batteries in the tool.

Table of Contents