Advanced Configuration; Mode Setup - Bahco TAWM Series Original Instructions Manual

Standard and slim electronic torque-angle wrench with memory
Hide thumbs Also See for TAWM Series:
Table of Contents

Advertisement

TAWM SERIES

ADVANCED CONFIGURATION

Advanced configuration is accessed from CONFIGURE menu selection on main menu.
Note: If wrench has been locked (see Preset Lock and Job Mode), a password entry is required
to enter Configure menu.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CONFIGURE menu selection using UP/DOWN buttons.
3. Press ENTER button to display Configure menu.
Menu Selections:
EXIT - Exits Configure menu and returns to target torque or angle screen.
MODE SETUP - Displays wrench mode setup menu.
PRESET LOCK - Displays Preset lock menu.
DELETE PRESETS - Displays delete all presets menu.
JOB MODE - Displays Job mode menu.
CALIBRATION - Displays wrench calibration menu (password protected).
SET DATE/TIME - Displays clock date and time entry screens.
SET CAL INTRVAL - Displays calibration interval setup screen (requires clock date and time setup).
CAL COUNT DOWN - Displays calibration needed countdown setup screen (requires clock date and
time setup and calibration interval setup) (only on SLIM wrenches).
CHANGE PASSWD - Displays change password menu.
ASSET # - Displays user configurable 15-character string (only on SLIM wrenches).
4. To exit Configure menu and return to target torque or angle screen, press ENTER button while
EXIT menu selection is highlighted.
STD
Note: All user configurable settings are stored in non-volatile memory and are retained while
power is off.

MODE SETUP

Mode setup menu allows user configure target torque and angle minus and plus tolerances and enable/
disable Torque THEN Angle mode and Torque AND angle mode.
1. From Configure menu, press ENTER button while MODE SETUP selection is highlighted.
2. Mode Setup menu is displayed.
Menu Selections:
EXIT - Exits Mode setup menu and returns to Configure menu screen.
TQ-% SETUP - Displays target torque minus tolerance entry screen.
TQ+% SETUP - Displays target torque plus tolerance entry screen.
ANG-% SETUP - Displays target torque minus tolerance entry screen.
SLIM
ANG+% SETUP - Displays target torque plus tolerance entry screen.
THEN DISABLED - Displays THEN Mode enable/disable screen.
AND DISABLED - Displays AND Mode enable/disable screen.
3. Use UP/DOWN buttons to highlight menu selections.
4. Press ENTER button while EXIT menu selection is highlighted to return to Configure menu.
STD
SETTING TARGET TOLERANCES
This function will allow user to set plus and minus tolerances for torque and angle targets.
Note: These tolerances are used for manual modes only. Preset tolerances are defined by Mini-
mum and Maximum values.
1. From Mode Setup menu, use UP/DOWN buttons to highlight tolerance selection to setup (TQ-%,
TQ+%, ANG-% ANG+%) then press ENTER button.
2. Tolerance screen is displayed.
3. Use UP/DOWN buttons to change tolerance value. Range is 0 to 10% ( factory default for minus
tolerance is 0% and 4% for plus tolerance).
4. Press ENTER button to accept selection and exit to Mode Setup menu.
STD
Note: Green progress lights turn on at target minus -% TOL.
Note: Red progress lights turn on above target plus +% TOL.
Note: Plus tolerance is added to minimum Preset value to define initial maximum value when a
Preset is first added.
ENABLE/DISABLE TORQUE THEN ANGLE MODE
This function will allow user to enable or disable Torque THEN Angle Mode.
1. From Mode Setup menu, use UP/DOWN buttons to highlight THEN DISABLED (factory default)
selection then press ENTER button.
2. TQ THEN ANGLE enable/disable screen is displayed.
3. Use UP/DOWN buttons to select ENABLE or DISABLE selection.
4. Press ENTER button to accept selection and exit to Mode Setup menu.
SLIM
SLIM
25

Hide quick links:

Advertisement

Table of Contents
loading