TAWM SERIES
STD
SLIM
Note: Menu selection indicates current configuration (ENABLED or DISABLED).
TORQUE THEN ANGLE MODE
Torque THEN Angle mode is setup by first setting a target torque and units then a target angle before
selecting Torque THEN Angle mode. In Torque THEN Angle mode, when applied torque reaches target
torque, wrench automatically switches to angle mode for angle measurement. Progress lights indicate
applied torque progress while torque is measured and angle when angle is measured. If torque is below
target torque when angle reaches target angle, green progress lights will not turn on and if angle exceeds
maximum angle, red progress lights turn on indicating a potential problem with fastener.
1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to select
torque measurement units then press ENTER button.
2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTER button.
3. Torque THEN Angle mode screen is displayed.
4. Apply torque until target is reached then rotate wrench to target angle.
STD
SLIM
Note: UNITS button can be used to select torque units while on Torque THEN Angle screen.
Note: Torque cycle is not recorded in memory unless both torque and angle reach targets.
Note: Red progress lights turn on if torque exceeds 110% of wrench full scale or if angle exceeds
target + plus tolerance while in manual mode.
Note: Torque THEN Angle Presets are entered by pressing and holding Units button while on
Torque THEN Angle screen. MAXIMUM TORQUE defaults to full range plus 10%. Refer to "Adding
a Torque Preset" and "Adding an Angle Preset" in Basic section for parameter entry.
ENABLE/DISABLE TORQUE AND ANGLE MODE
This function will allow user to enable or disable Torque AND Mode.
1. From Mode Setup menu, use UP/DOWN buttons to highlight AND DISABLED (factory default)
selection then press ENTER button.
2. TQ AND ANGLE enable/disable screen is displayed.
3. Use UP/DOWN buttons to select ENABLE or DISABLE selection.
4. Press ENTER button to accept selection and exit to Mode Setup menu.
STD
SLIM
Note: Menu selection indicates current configuration (ENABLED or DISABLED).
TORQUE AND ANGLE MODE
Torque AND Angle mode is setup by first setting a target torque and units then a target angle before selecting
Torque AND Angle mode. In Torque AND Angle mode, torque and angle are measured simultaneously.
Yellow progress lights track torque measurement. When both torque and angle reach their targets, green
progress lights turn on and torque and angle data record is stored. If either of measurements exceed their
upper tolerance, red progress lights turn on.
27