1. From Configure menu, use UP/DOWN buttons to highlight SET DATE/TIME selection then press
ENTER button.
2. SET DATE screen is displayed with year highlighted.
3. Use UP/DOWN buttons to set year then press ENTER button to highlight month.
4. Use UP/DOWN buttons to set month then press ENTER button to highlight day.
5. Use UP/DOWN buttons to set day then press ENTER button.
6. SET TIME screen is displayed with hour highlighted.
7. Use UP/DOWN buttons to set hour then press ENTER button to highlight minutes.
8. Use UP/DOWN buttons to set minutes then press ENTER button to highlight seconds.
9. Use UP/DOWN buttons to set seconds then press ENTER button.
10. Clock is set and Configure menu is displayed.
STD
SLIM
Note: Year selection will scroll up from 2013. Month selection will scroll from 1 to 12. Day selection will
scroll from 1 to 31.
Note: Hour selection will scroll through 0 to 23. Minute and Second selections will scroll through 0 to 59.
Note: If batteries are removed from wrench for longer than 20 minutes, clock will revert to default set-
tings and must be re-entered at power on.
SETTING CALIBRATION INTERVAL
This function will allow user to set calibration interval for when "CAL NEEDED" message will be displayed.
1. From Configure menu, use UP/DOWN buttons to highlight SET CAL INTRVAL selection then press
ENTER button.
2. CAL INTERVAL screen is displayed.
3. Use UP/DOWN buttons to change calibration interval.
Selectable Intervals: 12 MON (factory default); 6 MON; 3 MON; DISABLED
4. Press ENTER button to accept selection and exit to Configure menu.
STD
Note: Clock Date and Time must be set before calibration interval will function. If batteries are
removed from wrench for longer than 20 minutes, clock will revert to default settings and must
be re-entered at power on.
Note: Calibration interval is calculated from either IN-Service Date or last Calibration date (see
SHOW INFO menu) depending on which is more recent date. When clock Date is greater than
IN-Service or Last Calibration date, plus Cal Interval, "CAL NEEDED" message will be displayed
on power up and after a re-zero. Pressing ENTER button will continue to target menu. Applying
torque while "CAL NEEDED" message is displayed will immediately display torque or angle
measurement and return to target menu when released.
Note: As an alternative to calibration interval, a Calibration Cycle Counter is provided in Calibration
menu (Refer to Calibration Manual regarding Calibration menu). Each time a measurement cycle
reaches target torque, calibration cycle counter is incremented. When torque is recalibrated,
calibration counter is automatically reset to zero. User can disable calibration interval check and
use number of cycles since last calibration to decide when to recalibrate.
Note: If an invalid date is entered and Calibration interval is enabled, an unintended "CAL NEEDED"
message may be displayed. Either disable the calibration interval or enter a correct date.
SETTING CALIBRATION NEEDED COUNTDOWN (ONLY ON SLIM WRENCHES).
This function will allow user to set number of days when "CAL NEEDED" message will be displayed along
with days remaining before a wrench lock out occurs due to Cal interval expiring.
1. From Configure menu, use UP/DOWN buttons to highlight CAL COUNTDOWN selection then press
ENTER button.
2. CAL COUNTDOWN screen is displayed.
3. Use UP/DOWN buttons to change calibration countdown.
Range: 0 to 10 days.
4. Press ENTER button to accept selection and exit to Configure menu.