Bahco TAWM Series Original Instructions Manual page 8

Standard and slim electronic torque-angle wrench with memory
Hide thumbs Also See for TAWM Series:
Table of Contents

Advertisement

TAWM SERIES
STD
SLIM
ADDING A TORQUE PRESET
1. From manual target torque screen, select units of measure.
2. Press and hold UNITS button for 3 seconds.
3. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN
buttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.
4. TARGETTORQUE screen is displayed. TARGET TORQUE is target value of fastener. Initial TARGET
TORQUE value is value from target torque screen. TARGET TORQUE can be set to any value within
wrench torque range by pressing UP/DOWN buttons. Once desired target torque value has been
set, press ENTER button.
5. MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress
lights, audible alert and vibrator turn on. Initial MINIMUM TORQUE value is TARGET TORQUE value
minus negative torque tolerance (default 0%, see MODE SETUP in Advanced Configuration section).
MINIMUM TORQUE can be set to any value from TARGET TORQUE to wrench minimum torque range
by pressing UP/DOWN buttons. Once desired minimum torque value has been set, press ENTER button.
6. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which
red progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE value plus
positive torque tolerance (default 4%, see MODE SETUP in Advanced Configuration section).
Maximum torque value can be set greater than TARGET TORQUE value to 10% above wrench
maximum range by pressing UP/DOWN buttons. Once desired maximum torque value has been set,
press ENTER button.
7. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN buttons to increment/decrement batch count. Mode Count increments each time target
torque is reached if a batch count of zero is entered. Mode Count decrements if a non-zero batch
count is entered and resets to batch count value when count reaches zero. Once desired batch
count value has been set, press ENTER button.
8. PSET target screen is displayed labeled with next available PSET number from 01 to 50.
9. To enter additional torque presets, repeatedly press ENTER button until target torque screen is dis-
played and repeat steps above.
STD
SLIM
ADDING AN ANGLE PRESET
1. From manual target angle screen, press and hold UNITS button for 3 seconds.
2. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN buttons
then press ENTER button. NO menu selection returns to main menu without adding a PSET.
3. TARGET ANGLE screen is displayed. TARGET ANGLE is fastener rotational angle target value. Initial
TARGET ANGLE value is value from target angle screen. TARGET ANGLE can be set from 0 to 360° by
pressing UP/DOWN buttons. Once desired target angle value has been set, press ENTER button.
4. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is value at which green progress lights, au-
dible alert and vibrator turn on. Initial MINIMUM ANGLE value is TARGET ANGLE minus negative angle
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents