Preset Lock - Bahco TAWM Series Original Instructions Manual

Standard and slim electronic torque-angle wrench with memory
Hide thumbs Also See for TAWM Series:
Table of Contents

Advertisement

TAWM SERIES
1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to select
torque measurement units then press ENTER button.
2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTER
button until Torque AND Angle mode screen is displayed.
3. Apply torque and rotate wrench until both targets are reached.
STD
SLIM
Note: UNITS button can be used to select torque units while on Torque AND Angle screen.
Note: Torque THEN Angle Presets are entered by pressing and holding Units button while on
Torque THEN Angle screen. Refer to "Adding a Torque Preset" and "Adding an Angle Preset" in
Basic section for parameter entry.
Note: Torque cycle is not recorded in memory unless both torque and angle reach targets.
Note: Red progress lights turn on if torque exceeds target + plus tolerance or if angle exceeds
target + plus tolerance while in manual mode.
Note: Red progress lights turn on if torque exceeds maximum torque or if angle exceeds maxi-
mum angle in Preset mode.

PRESET LOCK

Preset Lock function allows user to lock wrench so that only configured presets are accessible. No other
presets can be configured and manual target torque and angle modes are not accessible when locked.
Note: Password entry is required to enable Preset Lock. When locked, password entry is required
to re-enter Configure menu (Refer to Calibration Manual regarding Configure password).
1. From Configure menu, use UP/DOWN buttons to highlight PRESET LOCK selection then press
ENTER button.
2. Preset Lock enable/disable screen is displayed.
3. Use UP/DOWN buttons to select LOCK or UNLOCK selection.
4. Press ENTER button to accept selection and exit to Configure menu.
STD
SLIM
Note: If LOCK is selected without a Preset configured, following screen is displayed:
STD
Note: When Preset Lock is enabled, Clear Memory function is disabled and displays following
Locked message if attempted:
STD
Note: When Preset Lock is enabled, Clear Cycle count function is disabled and displays Locked
message if attempted.
PRESET UNLOCK
When Preset Lock is enabled, a password is required to access Configure menu. Refer to Calibration
Manual for Configure password.
1. From target torque or angle screen, press and hold ENTER button for 3 seconds.
2. Highlight CONFIGURE menu selection using UP/DOWN buttons.
3. Press ENTER button to display Password screen.
4. Follow password entry procedure found in Calibration manual.