Introduction
The Capture/Compare Unit 6 (CCU6) is a high resolution 16 bit capture
and compare unit specially designed for motor control purposes.
The CCU6 unit is made up of a timer T12 Block with three
capture/compare channels and a timer T13 Block with one compare
channel.
Among other features, the CCU6 has the capability to capture external
input signals. In this example, the Input Capture Unit and the timer T12 of
the CCU6 module are used to capture a PWM signal and calculate its
frequency and duty cycle.