Operational Modes; Normal Mode; Settings Mode - Air Lift WirelessONE 25870 Installation Manual

Key fob activated compressor system
Hide thumbs Also See for WirelessONE 25870:
Table of Contents

Advertisement

OPERATIONAL MODES

Normal Mode : Mode in which the user can increase and decrease to the desired pressure,
as well as set and recall the three memory pressures. "LB" will be displayed on startup when
the battery is getting low.
Settings Mode: Mode in which the user can change the backlighting color, alter the unit of
measure (PSI, or BAR).

Settings Mode

1. Press and hold the Up and Down buttons for 5 seconds to enter the settings mode.
2. Once in the settings mode the display will display "SE" to indicate settings mode.
3. In the settings mode the M1 button (fig. 7) will scroll through all the backlighting options.
4. The M2 button (fig. 7) will toggle between the unit of measure for the pressure and
5. Pressing the UP and Down buttons together will exit back into the Normal Mode.

Normal Mode

Increasing desired pressure:
Decreasing desired pressure:
10
display "PS" for PSI and "BA" for BAR.
1. Initial press of any button will wake up display and not perform any function.
2. Upon wake up the LCD will display the desired pressure.
3. Pressing the up arrow will increment the desired pressure by 1PSI, or 0.1BAR
depending on the unit of measure selected.
When the user releases the button the new desired pressure will be
transmitted to the receiver.
4. Holding the up arrow will increment the desired pressure in units of 5PSI or 0.5BAR
depending on the unit of measure selected.
When the user releases the button the new desired pressure will be
transmitted to the receiver.
5. The Maximum pressure will be 120PSI or 8.3BAR.
• If desired pressure is max pressure then pressing the Up arrow will result
in no function.
1. Initial press of any button will wake up display and not perform any function.
2. Upon wake up the LCD will display the Desired pressure.
3. Pressing the down arrow will decrease the desired pressure by 1PSI, or 0.1BAR
depending on the unit of measure selected.
When the user releases the button the new desired pressure will be
transmitted to the receiver.
4. Holding the down arrow will decrease the desired pressure in units of 5PSI or 0.5BAR
depending on the unit of measure selected.
When the user releases the button the new desired pressure will be
transmitted to the receiver.
5. The Minimum pressure will be 0PSI or 0 BAR.
• If desired pressure is min pressure then pressing the Down arrow will result
in no function.
WirelessONE
MN-751

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wireles one 25870

Table of Contents