3. See F
. 23. Click the Edit button next to the Block
IG
Size field on the right side of the window. The Edit
Value window will open. Enter the number of Mod-
bus register addresses in the range from the start-
ing address entered in step 2 to the desired ending
address, inclusive. In this example, 7. The
addresses must be contiguous. This means that
each address must be available and addressable
from the ProMix 2KS. If one of the 7 addresses does
not exist within the ProMix 2KS Modbus structure,
the complete block will not communicate.
F
. 23: Setting Block Size
IG
312785B
Graco Gateway Network Communications Configuration