Product Id Number Read - Allen-Bradley 1203 Series User Manual

Remote i/o communications module
Table of Contents

Advertisement

B–8
Supported Block Transfer Messages

Product ID Number Read

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Product ID Number Read returns the product ID of the device to
which the Remote I/O module is connected.
PLC Block Transfer Instruction Data
PLC request instruction length: 3 words
Drive response instruction length: 4 words
Figure B.6
Message Structure
PLC Request
Message Length
Header Word 0
3
PLC Decimal Value
Header Word 1
256
0
Data Word 2
Product Code
Product Code
(Hex)
(Decimal)
0x02
2
0x03
3
0x07
7
0x10
16
0x11
17
0x12
18
0x13
19
0x14
20
0x15
21
0x17
23
0x18
24
0x19
25
0x20
32
0x22
34
Message Operation
Product ID Number Read, through the drive response message
word 3, indicates the type of device the Remote I/O module is
connected to. This value is defined in the message response chart
shown above.
If an error has occurred, word 1 of the response returns a negative
value of –32512.
Drive Response
Message Length
4
PLC Decimal Value
256 — Message OK
–32512 — Message Error
0
Product ID Number
or Error Code
Bulletin
Number
Product
1336S
1336 PLUS 0.5 – 10 HP
1336S
1336 PLUS 7.5 – 800 HP
1336F
1336 PLUS II
1336T
1336 FORCE w/PLC Adapter Board
2364F
2364 RGU DC Bus Regen Front End
1394
1394 Motion Drive
1557
1557 Medium Voltage AC Drive
193
SMP-3
150
SMC Dialog Plus
1305
1305 AC Drive
1397
1397 DC Drive
1336R
1336 Line Regeneration Package
1336T
1336 FORCE w/Standard Adapter Board
1336E
1336 IMPACT
Header
Word 0
Header
Word 1
Header
Word 2
Data
Word 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1203-gd11203-gk11336-gm1