Save/Recall/Initialize - Allen-Bradley 1203 Series User Manual

Remote i/o communications module
Table of Contents

Advertisement

B–16
Supported Block Transfer Messages

Save/Recall/Initialize

0
PLC request
4
Drive response
4
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Save/Recall/Initialize—NVS (Non-Volatile Storage) Functions—
activates the specified function. These functions are also referred to as
EEPROM functions.
PLC Block Transfer Instruction Data
PLC request instruction length: 4 words
Drive response instruction length: 4 words
Figure B.10
PLC Request
Message Length
4
PLC Decimal Value
–31998
0
NVS Command
Value
NVS Command
00
Not Used
01
NVS Save
02
NVS Recall
03
NVS Default Initialize
Message Operation
This function allows three different message requests:
NVS Save saves parameter information from the working
memory or RAM to NVS Storage.
NVS Recall retrieves the last saved data from NVS Storage and
places it in the working memory or RAM.
NVS Default Initialize clears the RAM and NVS Storage and sets
all parameter values to default.
If an error has occurred, response word 1 returns a value of -31998.
Example
This example requests the NVS Storage Save function be performed.
Data File Format
1
2
3
–31998
0*
0, 1, 2, or 3
770
0*
0*
* Example only — These values vary depending on parameters and products.
Message Structure
Header Word 0
PLC Decimal Value
Header Word 1
–31998 — Message Error
Header Word 2
Data Word 3
4
5
6
Drive Response
Header
Message Length
Word 0
4
Header
770 — Message OK
Word 1
Header
0
Word 2
Data
0 or Error Code
Word 3
7
8
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1203-gd11203-gk11336-gm1

Table of Contents