Fault Command Write - Allen-Bradley 1203 Series User Manual

Remote i/o communications module
Table of Contents

Advertisement

Fault Command Write

0
PLC request
4
Drive response
4
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Fault Command Write activates the Clear Fault, Clear Fault Queue,
and Drive Reset functions.
PLC Block Transfer Instruction Data
PLC request instruction length: 4 words
Drive response instruction length: 4 words
Figure B.11
PLC Request
Message Length
4
PLC Decimal Value
–30976
0
Fault Command
Value
Fault Command
00
Not Used
01
Clear Fault
02
Clear Fault Queue
03
Drive Reset (1336 FORCE Only)
Message Operation
The specified fault command function sends a fault handling request
to the device.
A Clear Fault request clears the last fault that occurred.
A Clear Fault Queue clears the entire fault buffer. Certain devices
may store more than one fault.
A Drive Reset is used with the 1336 FORCE drive product only.
This function resets the drive; it clears the fault queue and writes
the parameter information stored in NVS Storage to RAM.
Data File Format
1
2
3
–30976
0
0, 1, 2, or 3
1792
0
0*
For Warning Clear messages, the PLC decimal value is -30720. You can use three values:
0 = Not used, 1 = Clear Warning, and 2 = Clear Warning Queue.
For Warning Clear messages, a message OK returns 2048, and a message error returns
-30720.
* Example only — These values vary depending on parameters and products.
Supported Block Transfer Messages
Message Structure
Header Word 0
Header Word 1
PLC Decimal Value
–30976 — Message Error
Header Word 2
Data Word 3
4
5
6
B–17
Drive Response
Header
Message Length
4
Word 0
Header
1792 — Message OK
Word 1
Header
0
Word 2
Data
0 or Error Code
Word 3
7
8
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1203-gd11203-gk11336-gm1