14.3 Initial Diagnosis Sequence

LCD display Sequence
The LCD display sequence is shown in the Figure 14.1 . There are many patterns in the second line.
But, the following example shows only some of them.
SCF:initial
I/O Power on
diagnostic alarm
POST:Executing#
test_name
OBP stop
OBP:Initializing
Just a moment
ex:
Probing Memory
Probing CPU
Probing PCI
Scrubbing Memory
Booting
Operating System
Note that if hardware error is found during the power-on sequence, GP7000F main cabinet is power
cycled automatically to make sure any error detected during the power-on sequence.
If power-up processing is not performed after turning on the power switch, check to see if the AC
main line switch is in the proper position and that the mode switch is set to SECURE.
POST:ERR########
component
diagnostic stop
Figure 14.1
Power-on Sequence
14.3 Initial Diagnosis Sequence
########: error code
POST:ERROR STOP
OBP:STOP
check error logs
ex:
Check error logs
RED state trap
Reset swich