Fujitsu GP 7000F Manual page 137

M200, m200r, m400a, m400r, m600, m600r
Table of Contents

Advertisement

Installation specifications
Table 8.3
Item
Mass
Power condition
Maximum consumption current
Leakage current(1 for each cable)
Ground resistance
Temperature condition Operating
Humidity condition
Vibrations condition
Noise
Installation
*1:
*2:
Expansion Disk Cabinet Installation Specifications (1)
Specification
Up to 38kg
Single phase
Input voltage
100 to 120 VAC
(+-10%)
Input frequency
50/60 Hz (+2 to -4%)
3 A
1.2 mA or less
100ohm or less ( class C installation standard)
5 to 35 degrees Celsius (+41 to +95 F) (*1)
Not operating
0 to 50 degrees Celsius (+32 to +122F)
Operating
20 to 80%RH (no condensation)
Not operating
8 to 80% RH (no condensation)
Operating
0.2 G
Idle
0.4 G
47 db (A) (*2)
Standalone type
If the ambient temperature exceeds 35 degrees Celsius (+95F) during operation, a
warning message is displayed. Take steps to rectify the problem immediately.
The indicated noise is the mean value of the measurements obtained in an anechoic
chamber with less echoic influence. The actual noise measured at the installation site
may be greater than the indication noise due to surrounding noise and echoes.
8.4 Installation
Single phase
200 to 240 VAC
(+-10%)
1.5 A
2.7 mA or less
103

Advertisement

Table of Contents
loading

Table of Contents