CHAPTER 6 M600 Main Cabinet
Installation specifications
78
Table 6.5
Installation Specifications of M600 Main Cabinet (1)
Item
Mass
Power condition
Input voltage
Input frequency
Maximum consumption current
Leakage current (1 for each cable)
Ground resistance
Temperature condition Operating
Not operating
Humidity condition
Operating
Not operating
Vibrations condition
Operating
Idle
Noise
Installation
*1:
The mass shows M600 main cabinet without Expansion File Units.
*2:
If the ambient temperature exceeds 35 degrees Celsius (+95 F) during operation, a
warning message is output. Take steps to rectify the problem immediately.
*3:
The indicated noise is the mean value of the measurements obtained in an anechoic
chamber with less echoic influence. The actual noise measured at the installation site
may be greater than the indication noise due to surrounding noise and echoes.
Specification
Up to 250kg (approx.552 lb) (*1)
Single phase
Single phase
100 to 120 VAC
200 to 240 VAC
(+-10%)
(+-10%)
50/60 Hz (+2 to -4%)
13.4 A
6.6 A
2.2 mA or less
4.7 mA or less
100ohm or less ( class C installation standard)
5 to 35 degrees Celsius (+41 to +95 F) (*2)
0 to 50 degrees Celsius (+32 to +122F)
20 to 80%RH (no condensation)
8 to 80% RH (no condensation)
0.2 G
0.4 G
55 db (A) (*3)
Floor Stand type