CHAPTER 6 M600 Main Cabinet
Checking results of the memory diagnostics
Example for normal operation
Example of a slot #4 error
74
To check that the system recognizes installed memory modules correctly, execute the
"show-post-results" command at the ok prompt. A module that does not satisfy any
condition described in "Memory configuration" or a module judged to be faulty by memory
diagnostics is treated as an invalid module. The screen below lists the command execution results
related to memories and their meanings.
=== Memory =========
Type
:
EDO
Group
SLOT#
Size[Valid(MB)/Existing(MB)
A
0-3
256/256 256/256 256/256 256/256
4-7
256/256 256/256 256/256 256/256
8-11
-----
12-15
-----
B
0-3
256/256 256/256 256/256 256/256
4-7
256/256 256/256 256/256 256/256
8-11
-----
12-15
-----
*=Error SLOT
=== Memory =========
Type
:
EDO
Group
SLOT#
Size[Valid(MB)/Existing(MB)
A
0-3
256/256 256/256 256/256 256/256
4-7
256/256 256/256 256/256 256/256
8-11
-----
12-15
-----
B
0-3
0 /256
4-7
0 / 0*
8-11
-----
12-15
-----
*=Error SLOT
Note:
If a memory error is detected, an asterisk is displayed in the Size field for the
corresponding slot. In this example, an error in slot #4 of group B is detected in the
initial diagnostics operation. Modules in slots 0 to 3 and 5 to 7 of group B are
recognized as normal modules but also become invalid.
-----
-----
-----
-----
-----
-----:
-----
-----
-----
-----
-----
-----:
-----
-----
-----
-----
-----
-----:
0 /256
0 /256
0 /256
0 /256
0 /256
0 /256
-----
-----
-----
-----
-----
-----:
Total
2048/2048 MB
2048/2048 MB
Total
2048/2048 MB
0 /1792 MB