Important Information
Power supply
Rated voltage
230 V
Rated current
COMpact 5010 VoIP: max. 0.4 A
COMpact 5020 VoIP: max. 0.4 A
Protection class
I
Power
COMpact 5010 VoIP: 5 W min., 30 W max.
COMpact 5020 VoIP: 6 W min., 40 W max.
(dependent from the PBX´s expansion con-
figuration)
Modules
Power supply from the PBX
Environmental requirements
Operation
+0° ... +40° Celsius, avoid direct sunlight!
Operating the modules Installed in the PBX casing
Storage and shipping
-20° ... +70° Celsius
Humidity
10-90%, non-condensing
Connection options on the basic unit
Analogue internal
COMpact 5010 VoIP: 6 internal analogue
ports;
COMpact 5020 VoIP: 10 internal analogue
ports
ISDN internal/external
1 S
/U
0
internal U
switchable (jumper);
1 S
/U
0
port, switchable (jumper)
VoIP internal/external,
1 Ethernet port
PC an LAN
Printer
1 USB host for printer
Connection options on the COMpact POTS module
Analogue external
1
Connection options on the COMpact 2POTS module
Analogue external
2
Connection options on the COMpact 2ISDN module
ISDN internal/external
2 S
/U
0
port, internal U
switchable (jumper)
Connection options on the COMpact TSM module
Door station
1 power supply outlet
1 door terminal input/output
2 relay outputs
2 ringer inputs; one of which is used when
connecting an alarm/announcement contact
External devices to
3 relay outputs; two of which are used when
switch
connecting a door station
10
Technical data
10%, 50 Hz
port, optionally as internal S
P0
0
port or external S
port,
P0
0
port internal, optional as S
or U
P0
0
ports, optionally as internal S
P0
port or external S
port,
P0
0
Alarm/announcement
contact
Loud speaker/
Playback device
Internal analogue port
Connection unit
Type of dialling
Open-circuit voltage
Contact current
Range
Ring tone
Audible signals
Charge pulse
Impedances a/b
Internal S
Connection unit
port,
Connection type
P0
Supply voltage
Feeder
Devices
Range
Terminators
Internal U
Connection unit
0
Connection types
Range
Supply voltage
Feeder
External analogue port
Connection unit
1 alarm input
1 audio output/music input
Terminal clamp (2-core), for three port or
TAE jacks
Pulse or tone dialling
Max. 40 VDC
Approx. 21 mA
2 x 50 , approx. 800 m with 0.6 mm
Approx. 45 V
, configurable: 25/50 Hz
eff
425 Hz
5%, interval
Configurable: 12/16 KHz
Depending on the country variant Z
(220
+ 820
metrical
- port
0
Terminal clamp (4-core),
on the basic unit, Western/RJ-45 socket
(optional)
s
basis access as Point-to-Multipoint con-
0
nection, EURO-ISDN (DSS1)
40 V + 5% / – 15%
Max. 4 W
Max. 2 devices recommended (max. 8
ISDN devices, of which 2 max. devices are
without in-house feed, for example, various
ISDN telephones)
Max. 100-200 m (when laying bus lines; for
IAE connection technology, the European
standards ENV 41001 [DINV 41001] and
EN 28877 apply)
Switchable; Factory setting: on
port
P0
Terminal clamp (2-core),
on the basic unit, Western/RJ-45 socket
(optional)
U
with the Euro-ISDN protocol (DSS1);
P0
2 B-channels per port, direct connection to a
U
telephone or to the U
P0
Screened cable: up to 600 m;
unscreened cable: up to 1000 m
40 V + 5% / – 15%
Max. 4 W
RJ-11 socket
10%
R
/ 115 nF) or 600 ; sym-
/S
adapter
P0
0
Need help?