5.2.2 Control unit
5.2.2.1 To remove the control unit
1. Remove the wear guard below the battery housing.
To remove the wear guard from the battery
Refer to
housing on page 22 .
2. Disconnect the cable (A) and strain relief (B).
3. Disconnect the cable (C).
835 - 004 - 25.10.2019
4. Remove the 5 screws from the control unit.
B
A
5. Push and hold the control unit (D) carefully in the
direction of the arrow.
C
6. Release the support hook (E) and lift the control unit
(D).
D
E