Battery Troubleshooting
CT direction is towards the grid and the green power LEDs are ON. If the LEDs are not green indicating
l
import power - the CTs are reversed.
Battery Troubleshooting
The State line in the battery status screen should display one of the following: Charging, Discharging, Idle,
Off, Init.:
B S N :
X X X X X X X X X
S O E :
8 9 %
T o t a l :
S t a t e :
If error code 3x6B (or Error 186) - Battery Comm. Error appears, the battery communication is
l
disconnected. Check the following:
o
The RS485 control connection to the battery
o
The communication DIP switches settings on the battery
The ID DIP switches setting on the battery
o
If the state Idle is displayed instead of Charging/Discharging, check the following:
l
o
The system configuration
o
The DC connection
If Battery Internal Fault is displayed, refer to the battery documentation supplied with it.The
l
following is an example fault screen.
B a t t e r y
F a u l t
< x x x x >
< x x x x >
Fault # - according to battery
ID - The Modbus ID of the battery
<xxx> - text
28
Figure 22: Meter with CT
I D : 1 5
W W W W
P W R :
2 W
< x > W h
C h a r g i n g
I n t e r n a l
< # > ( I D :
1 5 )
StorEdge Interface Installation Guide MAN-01-00380-1.1