Connecting the StorEdge Interface

 
 

Connecting the StorEdge Interface to the Inverter

To connect to the inverter DC:
 1.  Prepare one pair of DC cables with MC4 connectors at both ends - male at one end and female at the 
other end. 
 2.  Connect one end of the cables to the inverter, and connect the other end   t o the DC+ and DC- input 
connectors marked INV OUT.
NOTE
If all the inverter DC inputs are connected to PV strings, use a branch cable (available from
SolarEdge) to connect the StorEdge Interface to the inverter DC input.
To connect RS485 communication between the inverter and StorEdge
Interface:
RS485 wiring specifications:
 
Cable type: Min. 3-wire shielded twisted pair (a shielded Ethernet cable (Cat5/5e STP) may be used)
l
 
Wire cross-section area: 0.2- 1 mm²/ 24-18 AWG (a CAT5 cable may be used)
l
 1.  Connect one end to the RS485 terminal block marked "RS485 to Inv." in the StorEdge Interface (see 
Figure 11):
 a.  Open gland #2.
 b.  Remove the seal from one of the openings and insert the wire through the opening.
-StorEdge Interface Installation Guide MAN-01-00380-1.1
Figure 10: StorEdge Interface connectors
Chapter 3: StorEdge Interface Installation