Nozzle Cleaning - Nordson AD-31 Series Product Manual

Extrusion handgun
Hide thumbs Also See for AD-31 Series:
Table of Contents

Advertisement

Maintenance
5-3
Nozzle Cleaning
@
@
@
A
WARNING:
Hot! Risk of
burns. Wear
heat-protective clothing,
safety goggles, and heat-protective gloves.
CAUTION:
Nozzles can be
damaged if an open torch, drill, or
broach is used for cleaning. Use only a pin-type probe to clean
anozzle.
1.
Relieve
system pressure following the instructions
in
your applicator
product manual.
WARNING:
Even
when switched
off, Nordson applicators and
guns
contain electrical potentials that can cause death.
Disconnect and lock out input power to the applicator main
circuit breaker.
NOTE:
Nordson
Type
R
fluid is used to clean adhesive from extrusion
systems.
lts advantages over similar
fluids are that
it
can
be reused and
that it has an inoffensive
odor.
2.
Disconnect
and lock out input power to the applicator main circuit
breaker.
4110132
Fig.
5-1
Power
Lock Out
O
1995
Nordson CorpoEtion
All rights
reserved
42-72
lssued
10/95
AsEN-06-[AD-31
EXI-1