EMC Connectrix B Series Hardware Reference Manual page 47

Hide thumbs Also See for Connectrix B Series:
Table of Contents

Advertisement

LED color &
LED name
behavior
Power Supply
No light
Status
Steady green
System Status
No light
-
1
Power supply/fan/assembly unit
2
AC power switch
3
Status LED
4
Captive screw
5
Power cord plug receptacle
6
Power cord retainer
CAUTION
!
Disassembling any part of the power supply voids the part
warranty and regulatory certifications. There are no
user-serviceable parts inside the power supply.
Because the cooling system relies on pressurized air, do not leave
either of the power supply slots empty longer than two minutes
while the switch is operating. If a power supply fails, leave it in the
switch until it can be replaced.
Maintain both power supplies in operational condition to provide
redundancy.
Table 3
describes the power supply status and system status LED
colors, behaviors, and actions required, if any.
Power Supply/Fan Assembly Unit Status LED Behavior, Description, and
Table 3
Required Actions
Description
Power supply is not receiving power or is off.
Power supply is operating normally.
System is off, boot is not complete, or boot
failed.
Remove and Replace System Components
Action required
Verify that the power supply is on and seated and
the power cord is connected to a functioning power
source.
No action required.
Verify that system is on and has completed
booting.
Installing a power supply/fan assembly
47