Page 1
Panorama & Panorama xl insert stove is exempt for use in smoke control areas when burning dry wood eCoDesiGn reaDy www.heta.dk Danish DesiGn . Danish QUality . Danish ProDUCtion...
Page 2
Signed on behalf the manufacturer of 02.12.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
Page 3
Signed on behalf the manufacturer of 02.12.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
Congratulations on your new wood stove insert, we are confident that you will be more than satisfied with your new Heta stove. Especially if you follow the following advice and instructions. The Panorama/Panorama XL is approved according to EN 13229, NS 3058 and NS 3059.
It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
Distribute the embers with the majority of them to the front. Place pieces of wood equivalent to about 1,9 kg (Panorama) and about 2,3 kg. (Panora- ma XL) on top of the embers perpendicular to the door.
1.7 explosion!!! Nominal heat out-put is 6,5 KW for Panorama and 9 KW for Panorama XL, equivalent to the It is very important never to leave operating air at about 80% open. The stove after start up or refueling, before the fire is established.
Flue gas temperature at the rated output is for ciency. At the same time, correct firing prevents Panorama 273°C and for Panorama XL 266°C environmental damage in the form of smoke relative to 20 ° C. Flue gas flow is 6 g / sec. for emissions and reduces the risk of chimney fires.
sure that the door seal and ash pan seal is intact Wood kg/m Willow kg/m and correctly fitting. Beech Wood If the stove it generating too little heat, this may Alder be because you are firing with wet wood. In this Scotch pine case, much of the heating energy is used to dry Larch...
1.13 troubleshooting table Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot. into the room.
1.14 maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
Removal sequence of stones. Replace in reverse order. Starting with Fig. 6. rear stone The rear stone on Panorama XL is divided into two. They are held together by a bracket on the rear side which is pressed down into the recesses.
1.18 Parts Panorama Pos. No. Name Qty. Pos. No. Name Qty. 0021-0047 Glass (4x512x646) 4020-0014 Handle 0023-3010 Textile glass 6 mm 5013-0007 Rep. set for handle with adhesive (2.31 m) 5013-0006 Complete rep. set self-close 1 5013-0005 Rep. set self-close, door...
1.18 Parts Panorama xl Pos. No. Name Qty. Pos. No. Name Qty. 0021-0048 Glass (4x512x906) 4020-0014 Handle with roller 0023-3010 Textile glass 6 mm 5013-0007 Rep. set for handle with adhesive (2.8 m) 5013-0006 Complete rep. set self-close 1 0023-3010...
The nominal output is the output to which the stove has been tested. The test was carried out with the combustion air 80%. 1.19 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no.
installation instructions Contents Installation instructions ..............17 Distance requirements ..............17 Floor ....................17 Chimney connection ................ 17 Combustion air ................. 18 Stovedrawings/measurments ............18 Clearances for installation ............... 19 Changing to a back outlet ..............20 Installation of the stove ..............21 Connecting of the external covection ducts ........
There must be adequate ding the distance between the two connections. space between the wall and the convection The Panorama, Panorama XL insert can be in- case. This is to avoid damage to the masonry/ stalled with a horisontal straight back outlet.
2.6 Panorama/Panorama xl Clearances for installation en 13 229 The Building materials that are used in safety test and shown in illustrations on this page, has a thermal conductivity of max. (= <0.36 W (m * K) 750 cm² insulated flue...
2.7 Changing to back outlet Mount the cover plate first and the the flue collar. To change to a back outlet, these items need to be ordered. 1 x 1525-0025 Flue collar 2 x 0008-1115 M6x25 1 x 1027-0301 Cover plate to convection case...
2.8 installation of the stove The entire convection case with the combustion chamber is to be adjusted for height by means of set screws. Fig. 1 Remove the vermiculite and the 4 seals in the combustion chamber - See page 12, and adjust through the holes in the bottom of the combu- stion chamber.
3. Connecting of the external covection ducts 2 x 1027-0295 - 4. Connecting external air supply from below Remove the vermiculite in the combustion chamber. See on page 12. 0032-0015 -...
Check that the air controller moves freely. Replace the vermiculite. See page 12. 5. Connecting external air supply from behind 1511-0028 - Possibly leakage around the coupling spigot can be sealed with heat resistant silicone or fire rope.
Page 24
”unauthorised volved administrations. fuel” for use within a smoke control area unless The Panorama/Panorama XL been recommen- it is used in an ”exempt” appliance (”exempted” ded as suitable for use in smoke control areas from the controls which generally apply in the when burning dry wood logs.