With your new stove you should have The Scan-Line 550 inset stove has received the following: been approved according to the EN 13229, DIN+, and 15a B-VG.
The stove must never be connected ture at nominal output is 290°C when to chimneys that are also linked to expelled to an exterior temperature of a gasfired heater. An efficient stove 20°C. The flue gas mass flow is 6 g/ makes high demand on chimney pro- sec.
Page 4
Combustion air flow • Only approved materials may be used from the ventilation unit to The insert stove is approved as a the air inlet vent. room air-dependent insert stove in • The air inlet vent must be fitted accordance with EN 13229. All the correctly and insulated to prevent combustion air flow in the inset stove formation of condensate.
Page 5
Chimney Flue collar Inset stove Convection box Installing the inset stove into the convection box 1. Remove the magnet fittings from screws at the back of the combu- the convection box to ease the stion chamber. The top screw has installation.
Page 6
The top screw has to go through both the combustions chamber and the convection box. The bottom screw has to be screwed against the convection box as back pressure. Magnet fittings Screws for fitting the front frame Front frame Fitting the collar for external air inlet 1.
Page 7
Sealing cord Collar for external air inlet 2 springs Air damper for the secondary airflow...
INSTRUCTIONS FOR USE ter of more than 10 cm should be split First firing before storing. The pieces of firewood The stove has been treated with a should be of an appropriate length (ap- heat-resistant coating which hardens prox. 25 cm) so that they can lie flat at a temperature of approximately 250 on the bed of embers.
release At combustion 1000 litres of heating Open Closed oil forms 3.171 tons CO . As wood is a CO neutral heat/ energy source, you save the environment about 1.3 kg CO every time you have used 1 kg normal wood.
Please note that the start-up Please note that the stove will, natu- mechanism must not remain open du- rally, produce soot if the secondary air ring normal operation of the stove, as intakes are closed completely. This will this may lead to overheating. It must only prevent oxygen from being drawn into be used until the fuel is burning with a the stove, and the viewing window and...
GUARANTEE Heta inset stoves are subjected to Damage resulting from incorrect use stringent quality control procedures Transport costs in connection with re- both throughout the produc-tion pro-...
Page 12
Cleaning after sweeping the chimney and replacing the stones. Fig 3-4...
Need help?
Do you have a question about the SCAN-LINE 550 and is the answer not in the manual?
Questions and answers