Heta Prestige Series Operating And Installation Instructions

Heta Prestige Series Operating And Installation Instructions

Insert stove

Advertisement

Quick Links

OPERATING AND INSTALLATION
INSTRUCTIONS
PRESTIGE INSERT STOVE
THE PRESTIGE / PRESTIGE SCA SERIES IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN
BURNING DRY WOOD
Prestige A
Prestige BL
Prestige BR
Prestige C
www.heta.dk
EN
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
1

Advertisement

Table of Contents
loading

Summary of Contents for Heta Prestige Series

  • Page 1 OPERATING AND INSTALLATION INSTRUCTIONS PRESTIGE INSERT STOVE THE PRESTIGE / PRESTIGE SCA SERIES IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD Prestige A Prestige BL Prestige BR Prestige C www.heta.dk DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION...
  • Page 2 Signed on behalf the manufacturer of 05.10.2016 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 3: Table Of Contents

    The Prestige series have been approved according to the EN 13240, NS 3058/3059 and 15a BVG and the Prestige SCA series are modified so that they are also re- commended as exempt for use within smoke control areas (SCA) throughout the UK (see clean air act Appendix A).
  • Page 4: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 5 Leveling set screw 0008-0013 1 x 0032-0027 8120-0000-DK 8120-0100-DK External air 8120-0200-DK 8120-0300-DK DOP-Pres�ge Indsats-2237-2016 Data plate Heta A/S . Jupitervej 22 7620 Lemvig . Denmark 2016 Produk�ons år: DS/EN 13229/A2:2004/NS 3058/3059 from behind Produkt beskrivelse Serie nr: Pres�ge Indsats Lukket ildsted For indbygning Brændsel...
  • Page 6: Operating Instructions

    1. OPERATING INSTRUCTIONS 1.1 Before using feed the fire producing negligible amounts of smoke and unburnt hydrocarbons. The applian- Before the wood stove is used make sure ces will only be considered as an exempt appli- required installation conditions, are met. See ance if this stop is in place.
  • Page 7: Refueling

    Note: Vermiculite If the fire dies down completely or embers are (stone) smoldering, then it will be necessary to place Maximum some screwed up paper or firelighters onto wood filling the grate with some kindling or small pieces of wood to reestablish the fire once again. Leave the air slider fully open and allow the fire to build before refueling with larger pieces of wood and then adjust the slider for optimum combustion.
  • Page 8: Risk Of Explosion

    • Chimney is blocked timal combustion and the highest possible ef- • Air tight house (lack of combustion air supply) ficiency. Heta wood stoves are constructed so • Poorly placed chimney for the surroundings, that it itself provides an optimal blend of com- for ex.
  • Page 9: Operational Problems

    dry wood in your stove. Never use your stove of about 4.18 kW / hour per kg, and one litre to burn driftwood, as this may contain a lot of heating oil contains about 10 kW / hour. salt which can damage both the stove and the release chimney.
  • Page 10: Troubleshooting

    1.13 Troubleshooting table - applies to all stove types Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot.
  • Page 11: Maintenance

    1.14 Maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
  • Page 12: Cleaning/Replacing Bicks After Chimney Sweeping

    1.17 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Removal sequence of stones. Replace in reverse order. Starting with Fig. 8.
  • Page 13: Stove Data Table En 13229

    The nominal output is the output to which the stove has been tested. The test was carried out with the combustion air 40%. 1.19 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no.
  • Page 14: Parts

    1.20 Reservedele Prestige Model A, BR, BL og C 13 - 12 - 40 - 41 - - 42 39 - Prestige A - 43 Prestige BR - Prestige BR - Prestige BL Prestige C 38 - 11 - 37 - - 36 10 - - Prestige A...
  • Page 15 Pos. No. Name Qty. Pos. No. Name Qty. 0023-0213 Top Back stone, left 26 1513-0123 ** Closing System 0023-0215 Left baffle 27 1505-0084 *** Left-hinged door 0023-0214 Right baffle 28 5013-0011 Rep. set glass clips sidelight 0023-0212 Lower back stone, left 29 0021-0066 Side Glass, large 0023-0211...
  • Page 16: Installation Instructions

    Installation Instructions Contents Installation instructions ..............17 Distance requirements ..............17 Floor ....................17 Chimney connection ................ 17 Combustion air ................. 18 Stovedrawings/measurments ............19 Fitting the flue collar ................20 Clearances for installation EN 13 229 ......... 20-21 Installation of the stove ..............22 Connecting external air supply from below ........
  • Page 17: Installation Instructions

    We recommend that you let a 2.2 Floor professional Heta dealer install the stove. Alter- natively, you can ask the local chimney sweep You must ensure that the floor can support the before installation.
  • Page 18: Combustion Air

    fireproof material and / or • The air inlet vent must be fitted correctly and beading. Heta A/S stresses that it is of utmost insulated to prevent formation of condensate. importance that this is done correctly with very The cross section of the vent and grille must tight joints.
  • Page 19: Stovedrawings/Measurments

    2.5 Stovedrawings/measurments Measurment Prestige A Measurment Prestige BR Measurment Prestige BL Measurment Prestige C...
  • Page 20: Fitting The Flue Collar

    2.6 Fitting the flue collar The flue collar is bolted to the stove from inside the fire chamber with, 4 x M6x10 0008-1117. 2.7 Clearances for installation EN 13 229 The Building materials that are used in safety test and shown in illustrations on this page, has a thermal conductivity of max.
  • Page 21 Insulated with min .: 25 mm Min. 1080 cm Lambda value (W / mK): 0.046 insulated flue pipe 1100 Min. 580 cm Not combustible material Combustible material Other combustible material The dimensions are the minimum dimensions, unless otherwise stated. Distance to flamable materials Minimum dimensions in mm Variant 400*...
  • Page 22: Installation Of The Stove

    Prestige BR, BL, C Prestige BR, BL, It is up to the installer to assess if the support rod is required for the specific structure.Heta It is optional whether you want to mount the A/S disclaims any liability for all types of dama- support rod1516-0007.
  • Page 23 Prestige C Prestige BR Prestige BL Prestige C Prestige A Prestige A Prestige BR Prestige BL Prestige BR, BL, C Prestige BR Prestige BL Prestige BR Prestige BL...
  • Page 24: Connecting External Air Supply From Below

    Prestige C Prestige C Prestige C 3. Connecting external air supply from below 5 x M4x8...
  • Page 26: Connecting External Air Supply From Behind

    4. Connecting external air supply from behind The Scan-Line Prestige models Model Model Prestige A Prestige BL 8120-0000 8120-0200 without side windows with side window in the left side. Left-hinged door or right-hinged door Left-hinged door or right-hinged door Model Model Prestige BR Prestige C...
  • Page 27 5. Appendix A The Clean Air Act 1993 and Smoke Control Areas. Under the Clean Air Act local authorities may gulatory Reform (Scotland) Act 2014. In Wales declare the whole or part of the district of the and Northern Ireland these are authorized by authority to be a smoke control area.

This manual is also suitable for:

Prestige aPrestige blPrestige brPrestige c

Table of Contents