5. MAINTENANCE

DO NOT carry out any maintenance unless you are suitable qualified to do so.
If in any doubt please contact your dealer for advice and guidance.
5.1. Before attempting any maintenance jobs on the compressor, make sure of the
following:
5.1.1. That the unit is unplug from the electrical supply.
5.1.2. The master power switch in position "0".
5.1.3. There is NO pressure in the air tank.
5.2. After every 50 hours of duty;
5.2.1. We advise you to dismantle the air filter (1) and clean the filtering element
by blowing it through with compressed air.
5.2.2. It is recommended that you replace the filter element as required and more
often if the compressor operates in a dusty environment.
5.3. The compressor generates condensate water which accumulates in the tank.
5.3.1. The condensate in the tank must be drained at least once a week, by opening
the drain tap (1) under the tank.