3.2
Assembly
3.2.1
Preparing mounting
Converting the flush actuation
Viega Mono WC block
Actuation can take place optionally from the front or the top. The actua-
tion is pre-mounted from the front in delivery condition. To convert
actuation from above, proceed as follows:
Remove the front cistern cover.
Press the bow of the drain valve backwards from the bracket of the
mechanism.
Turn the mechanism's lock by 90° in an anti-clockwise direction.
ð The mechanism is unlocked and can be removed.
Handling
14 from 26