3) Place
A4
(LTR) paper in the cassette or the manual feed tray.
4) Open the ADF, and place an A5 (STMTR) original on the copyboard glass.
5) Close the ADF, and make a copy in Direct.
6 ) Check the copy image, and check to make sure that the area outside the image is free of
fogging.
7) If fogging is found, the position of the white sheet may be wrong; check its positioning.
If no fault is found, try skew removal once again.
1.3.3.2 LeWRight Registration Adjustment
Using the ADF, make
a
copy of the sheet in Direct, and check to make sure the leftlright
registration is 10
+
1 mm. (See 1.2.2 of Chapter 7.)
1) Pick the tab [I], and detach the white plate [2].
(feeding direction)
COPYRIGHT Q 2002 CANON INC.
CANON P C l W ~ u n a g e C W
DGWs
REV.
1
AUG. 2W2
F07-103-03
...
. . . -
Copy of the test sheet