Specifications - Yale HSA6600 Installation Manual

Hsa app alarm kit
Table of Contents

Advertisement

10

Specifications

All devices
Environmental Conditions
-10°C to 40°C, relative humidity 70% non-
condensing for all units except the external Siren.
Siren: -20°C to 50°C, relative humidity 95% non-
condensing
Radio operational range
30m in a typical domestic installation, range can vary
depending on building construction, device positions
and RF environment
Housings
ABS/polycarbonate
Hub
Siren Output no built in siren
Zones 20 radio devices
Radio system 433MHz
Power supply Plug top adaptor type, input 230VAC
50Hz, output 9VDC, 1A, tested to EN 60 950
Rechargeable battery Ni-MH, 4.8V 300mAH,
charge time 72hrs, standby time 2hrs
External Siren
Siren Output 104dBA sound
pressure @ 1m minimum
Radio 433MHz FM
Power supply 6V, 4 x D alkaline batteries.
PIR Motion Detector
Alarm processing Microprocessor controlled
dual edge sequential pulse count with pulse length
discrimination
Radio 433MHz FM
Power supply 4.5V, 3 x AAA alkaline batteries.
Motion Detector range 12 metres 110
Door/Window Contact
Radio 433MHz FM
Power supply 3V, CR2032 lithium coin cell battery
Smoke Detector
Radio 433MHz FM
Power supply 4 x AAA alkaline batteties
Tested to EN54
Key Fob
Radio 433MHz FM
Power supply 3V, CR2032 lithium coin cell battery.
Key Pad
Radio 433MHz FM
Power supply 3V, CR2032 lithium coin cell battery.
Panic Button
Radio 433MHz FM
Power supply 3V, CR2032 lithium coin cell battery.
Special notes on compatibility:
This alarm system is NOT compatible with EF
series, AC series and SR series accessories. This
alarm system is only compatible with HSA alarm
accessories. Please note the prefix "HSA" on the
front of the part number to indicate compatibility.
The phone feature and remote notifications
require our central server. Yale reserves the
right to charge for this service in the future.
We would contact individual users via e-mail
should this situation change.
In the event of server disconnection, the alarm
system will continue to function (arm/disarm)
using the supplied Key Pad accessory.
The smart phone feature requires our central
server. Yale offers no guarantee on the
availability of our server. Yale cannot guarantee
O
limitless availability of our free server. We would
contact individual users via e-mail should this
situation change. Alarm Notification functions
must only be used with people who have
consented to being contacted by the system.
Information and illustrations are subject to
changes within this document. Yale reserves
the right to alter the specifications and product
design at any time without notice.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsa6610

Table of Contents