Turn Off The Power Supply; Front Panel; Power Cable - Mitsubishi Electric JT-SB116JH2-S-NA Handbook

Hide thumbs Also See for JT-SB116JH2-S-NA:
Table of Contents

Advertisement

The following pictures show JT-SB116JH2-W-NA.

( 1 ) Turn off the power supply.

1 Stop the operation.
2 Turn off the circuit breaker on the distribution board.

(2) Front panel

1 Draw out the tank assembly (assy).
2 Unscrew the clamping screws, and remove the front panel.
(Two special (spl) screws 4×16, indicated by )

(3) Power cable

1 Unscrew the clamping screw, and remove the terminal block (TB)
cover.
(One PTT screw 4×6, indicated by )
2 Unscrew the clamping screws, and disconnect the power cable
leads.
(Two screws, indicated by )
─ 17 ─
Tank assy
Front panel
Ground wire
Terminal block
Power cable
TB cover
Power cable
Terminal block