Mitsubishi Electric JT-SB116JH2-S-NA Handbook page 13

Hide thumbs Also See for JT-SB116JH2-S-NA:
Table of Contents

Advertisement

Error Mode Display
Power
Heater
or
(Tamper-proof timer)
Power
Heater
(Motor step-out)
(Motor lock)
(Motor overspeed)
Power
Heater
( Motor current detection
error)
Power
Heater
( Overvoltage/Undervoltage
detection)
Power
Heater
( Motor signal error)
Power
Heater
(Microcomputer error)
Checkpoint
Dirty sensor
Dirt may shield the sensors. Wipe the dirt off the sensor window.
window
Remaining foreign
Check for any objects left over and shielding the sensor in the hand
object
drying area.
Connector dis-
Check if the following connectors are disconnected.
connection for the
1 Sensor circuit board (JT-30S3R) connector CN12
sensors
2 Sensor circuit board (JT-30S2R) (2 locations) connectors CN15
3 Light receiving circuit board connector CN11
4 Control circuit board connectors CN7 and CN8
Malfunction of
If no error is found after checking the above, replace the control
the control circuit
circuit board.
board
Motor malfunction Check that the motor is not locked and turns smoothly by hand.
Malfunction of
If no error is found after checking the above, replace the power
the power circuit
circuit board.
board
Blower (assem-
If the error display persists after replacing the power circuit board,
bly) malfunction
replace the blower (assembly).
Motor overload
Check for causes of motor overload. (Too much higher power sup-
ply voltage, any object disturbing the motor revolution, etc.)
Connector dis-
Check if the motor lead wire connectors (black, white, and red) are
connection for the
disconnected.
motor
Blown thermal
Measure the resistance between Red and White and between Red
fuse of the motor
and Black of the motor lead wires. If it is ∞ Ω, replace the blower
(assembly).
Malfunction of
If no error is found after checking the above, or if the error display
the power circuit
persists after replacing the blower (assembly), replace the power
board
circuit board.
Abnormal power
Check that correct power supply voltage is applied.
supply voltage
• The error will occur if the power supply voltage is approx. 170 V
AC or over, or approx. 60 V AC or under.
*Note: If 170 V AC or over is applied, a current fuse on the power
Malfunction of
If no error is found after checking the above, replace the power
the power circuit
circuit board.
board
Connector discon-
Check if the connector CN5 on the control circuit board, CN2 on
nection
the power circuit board, or CN30 or CN31 on the filter circuit board
is disconnected.
Malfunction of
If no error is found after checking the above, replace the control
the control circuit
circuit board.
board
Malfunction of
Replace the control circuit board.
the control circuit
board
Check Method and Remedy
circuit board may blow.
─ 13 ─

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jt-sb116jh2-w-naJt-sb116jh-g-naJt-sb116jh-w-na

Table of Contents