Danger due to rotating parts: impeller!
The danger of shearing due to the rotating impeller can exist even when the machine off, if it is started manually.
Therefore use suitable work clothes and personal protection equipment.
The position of the silencer housing can be changed by using the manifold (on request).
NOTE FOR THE USER
See silencer housing repositioning diagrams in the first section.
5.3.1
90° MANIFOLD (accessory) USE
For different connection configurations, use the 90° manifold installed
only on the cover openings.
See the possible configurations as previously illustrated.
Fitting the 90° manifold
Remove the silencer as previously described.
Insert the gaskets between the cover and manifold.
Tighten the respective screws
Assemble the silencer by proceeding in reverse order.
See par. 5.1 for INSTALLATION CONDITIONS
5.4

VERTICAL INSTALLATION ON THE COVER

The units can be installed with the working axis vertical, as follows:
Using vibration dampers fitted directly on the cover, without manifold.(E)
Using a special foot for vertical fixing, available as an accessory.(F)
Non-compliance with the unit's intended use can cause serious
injury.
Regularly check the fixing of the unit to the support structure.
Excessive vibration of the unit can seriously damage the machine.
Avoid the possibility of water stagnation, especially in case of
ATTENTION!
installation of the unit with vertical axis.
ATTENTION!
Check the motor rotation direction.
DIRECTION)
A special foot is available as an accessory for fixing the unit vertically
on the cover. The foot has holes for fixing; use all the holes and
NOTE FOR THE USER
choose the appropriate type of screw.
The vibration dampers are not included but are available on request.
NOTE FOR THE USER
5.5

ELECTRIC MOTOR

Danger due to electricity!
• Improper behaviour can cause serious injury.
• Work on the electrical equipment (installation, maintenance) must only be carried out by qualified and authorised electricians!
• Before starting work on the unit or system, take the following precautions:
- make sure the machine is NOT powered;
- take steps to prevent the power from being reconnected;
- open the terminal box only after making sure the power is disconnected!
• The terminal box must not contain:
- foreign bodies;
- impurities;
- moisture.