WAGNER POWERPAINTER 90 EXTRA Translation Of The Original Operating Instructions page 26

Hide thumbs Also See for POWERPAINTER 90 EXTRA:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
GB
For reasons of function, safety and durability, only use genuine WAGNER high-pressure hoses and spray
i
nozzles. For overview see „Spare parts lists".
The risk of damage rises with the age of the high-pressure hose.
i
Wagner recommends replacing high-pressure hoses after 6 years.
Connecting the device
A properly earthed socket outlet with earthing contact must be used for connection. The connection must be equipped
with a residual current protective device with INF ≤ 30 mA.
Setting up the unit
When working indoors:
Vapors containing solvents may not be allowed to build up in the area of the device.
Setting up the unit on the side a way from the sprayed object.
Danger
A minimum distance of 5 m between the unit and spray gun is to be maintained.
When working outdoors:
Vapors containing solvents may not be allowed to blow toward the unit.
Note the direction of the wind.
Set the unit up in such a way that vapors containing solvents do not reach the unit and build up there.
A minimum distance of 5 m between the unit and spray gun is to be maintained.
Maintenance and repairs
Before carrying out any work on the device, relieve the pressure and unplug the power plug from the socket.
Danger
Cleaning the unit
Danger of short circuit through penetrating water!
Never spray down the unit with high-pressure or high-pressure steam cleaners.
Danger
Cleaning units with solvents
When cleaning the unit with solvents, the solvent should never be sprayed or pumped back into a container
with a small opening (bunghole). An explosive gas/air mixture can be produced. The container must be
earthed.
Do not use flammable materials for cleaning purposes.
Danger
Earthing of the object
The object to be coated must be earthed.
Thermal release
The device is equipped with a thermal release which disconnects the device in case of overheating. In this case switch the device
off, turn the selector switch to the PRIME position (vertical), remove the mains plug and allow device to cool down for min. 30
minutes. Eliminate the cause of heating, e.g. slots for air intake covered.
1 Pressure regulator
3 Inlet valve pusher
5 Telescopic handle
7 Nozzle holder
9 ON / OFF Switch (0 = OFF, I = ON)
11 Filter (white)*
13 High-pressure hose
20
Description (Fig. 1)
2 Hose connection
4 Hose holder
6 Spray Gun
8 Nozzle 517
10 Selector switch
12 Tool box
14 Return line
PowerPainter 90 EXTRA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerpainter 90 extra

Table of Contents